OSHA Inspection: TANK SOLUTIONS INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TANK SOLUTIONS INC. in 533 INDUSTRIAL PARK ROAD SUITE 2, SMOCK, PA 15480 (NAICS 423510). OSHA activity number 340874577.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tank Solutions INC. — free Get an email when a new federal OSHA severe-injury report for Tank Solutions INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TANK SOLUTIONS INC.
Site address
533 INDUSTRIAL PARK ROAD SUITE 2
City
SMOCK
State
PA
ZIP
15480
Mailing
533 INDUSTRIAL PARK ROAD SUITE 2, SMOCK, PA 15480
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
41
Ownership type
A

6 citations on file for this inspection.

1910.107 B05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 18, 2015
Abate by
Sep 24, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.107(b)(5)(ii): Discarded filter pads and filter rolls were not immediately removed to a safe, well-detached location or placed in a water-filled metal container and disposed of at the close of the day's operation unless maintained completely in water:    a) In the 420 Shop, on or about August 26, 2015 - Used Paint Pockets, Overspray Arrestor Pads, were not immediately removed or placed in a water-filler metal container after they were changed out of the open face spray booth two days prior.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.107 B05 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 18, 2015
Abate by
Dec 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a) In the Main Shop, on or about August 26, 2015 - Space within the Global Finishing Solutions cross draft spray booth on the upstream side of Paint Pockets, Overspray Arrestor Pads, was not protected with approved automatic sprinklers.    b) In the 420 Area, on or about August 26, 2015 - Space within the open face spray booth on the upstream side of Paint Pockets, Overspray Arrestor Pads, was not protected with approved automatic sprinklers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 4 instances 2 exposed
Issued
Sep 18, 2015
Abate by
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift:   a) In the Main Shop, on or about August 26, 2015 - The quantity of acetone used for cleaning pots and spray guns being stored adjacent to the Global Finishing Systems cross draft spray booth exceeded the minimum required.  b) In the Main Shop, on or about August 26, 2015 - The quantity of Carboline Thinner 225 E mixed with the paint that is spray applied to tanks being stored adjacent to the Global Finishing Systems cross draft spray booth exceeded the minimum required.  c) In the 420 Shop, on or about August 26, 2015 - The quantity of acetone used for cleaning pots and spray guns being stored adjacent to the open face spray booth exceeded the minimum required.  d) In the 420 Shop, on or about August 26, 2015 - The quantity of Carboline Thinner 225 E mixed with the paint that is spray applied to tanks being stored adjacent to the open face spray booth exceeded the minimum required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Sep 18, 2015
Abate by
Sep 30, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  a) In the Main Shop, on or about August 26, 2015 - The employer did not implement a change schedule for painters required to wear 3M half mask air purifying respirators with 3M 6001 organic vapor cartridges while spray coating tanks in a cross draft spray booth.  b) In the 420 Shop, on or about August 26, 2015 - The employer did not implement a change schedule for painters required to wear 3M half mask air purifying respirators with 3M 6001 organic vapor cartridges while spray coating tanks in an open face spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 18, 2015
Abate by
Sep 30, 2015
Penalty
Initial $2,100 · Current $1,800 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met and which also includes criteria specified in 29 CFR 1910.1200(e)(1)(i) (e)(1)(ii):    a) At the facility, on or about August 26, 2015 - The employer did not develop a written hazard communication program.  Painters spray paint tanks with a mixture of Carboline Thinner 225 E, Carbothane 8845 Part A and Carboline Urethane Converter 8843.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2100

1910.1200 F06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 18, 2015
Abate by
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  a) In the Main Shop, on or about August 26, 2015 - A 55 gallon drum containing waste from cleaning the pots and the spray gun was not labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v). The pots and spray gun contained Carboline Thinner 225 E, Carbothane 8845 Part A and Carboline Urethane Converter 8843.