HIGBEE, MO —
OSHA Inspection: MIDWEST STAVE EXCHANGE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MIDWEST STAVE EXCHANGE in 739 EVAN ST, HIGBEE, MO 65257 (NAICS 321920). OSHA activity number 340875004.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDWEST STAVE EXCHANGE
- Site address
- 739 EVAN ST
- City
- HIGBEE
- State
- MO
- ZIP
- 65257
- Mailing
- 15400 HWY B, HIGBEE, MO 65257
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 13
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 D01
- Issued
- Sep 22, 2015
- Abate by
- Oct 25, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) Storage Area above Break Room/Office: Employees were exposed to overhead hazards as there was no load rating posted for the storage area above the Break Room and Office where motors were being stored.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.147 C04 I
- Issued
- Sep 22, 2015
- Abate by
- Oct 25, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Splitter Saw: Employees were exposed to electrical and amputation hazards as a written lockout tagout program was not available onsite. Procedures were not being utilized for the control of potentially hazardous energy when the Splitter Saw for stave barrels had welding work done on the brace and the Splitter Saw was not locked out until the work was completed.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.178 L02 II
- Issued
- Sep 22, 2015
- Abate by
- Oct 25, 2015
- Penalty
- Initial $1,200 · Current $500 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. (a) Forklift operators were subject to struck by hazards as they had not received initial forklift training from their employers and additional training every three years.
Recent events (2)
- — I (S) $500
- — Z (S) $1200
1910.178 P01
- Issued
- Sep 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) Production: Employees were exposed to struck by hazards as the Clark Forklift did not have a working horn, and the control levers were not marked.The forklift was not taken out of service until restored to a safe operating condition.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Sep 22, 2015
- Abate by
- Oct 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) Throughout facility: Employees were exposed to struck by hazards as the Clark forklift was not inspected daily before being placed in service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Sep 22, 2015
- Penalty
- Initial $1,600 · Current $500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Bandsaw: Employees were exposed to unguarded pinch points as a section of the metal skirting was missing on the bandsaw turntable.
Recent events (2)
- — I (S) $500
- — Z (S) $1600
1910.305 B02 I
- Issued
- Sep 22, 2015
- Penalty
- Initial $1,600 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) West Wall by Splitter Saw: Employees were exposed to electrical hazards as the electrical outlet with orange tape that was mounted on the west wall did not have a cover.
Recent events (2)
- — I (S) $500
- — Z (S) $1600
1910.305 G01 III
- Issued
- Sep 22, 2015
- Abate by
- Oct 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: (a) Electrical Panel by Office/Break Room: Employees were exposed to electrical hazards as a wire was subjected to abrasion as it was run directly through the east wall for the electrical panel next to the blower disconnect.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Sep 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) Splitter Saw Area, West Wall: Employees were exposed to electrical shock as the wire to the 208/240 outlet did not have adequate strain relief for the electrical cord entering the box. (b) Bandsaw Area: Employees were exposed to electrical shock as the extension cord with an plastic outlet box to power the blower did not have adequate strain relief from the electrical cord to the box. (c) Bandsaw Area: Employees were exposed to electrical shock as the flexible conduit to the Cutler Hammer Control electric box did not have adequate strain relief where the conduit met the electrical box on the top of the electric box, and did not have adequate strain relief where the electrical wiring exited the base of the electrical box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Midwest Stave Exchange
View Midwest Stave Exchange's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340875004.