Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CREW CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CREW CONTRACTING in 1529 CRESCENT ROAD, CLIFTON PARK, NY 12065 (NAICS 238130). OSHA activity number 340876804.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crew Contracting — free Get an email when a new federal OSHA severe-injury report for Crew Contracting is published. One employer, no account, unsubscribe in one click.
Establishment
CREW CONTRACTING
Site address
1529 CRESCENT ROAD
City
CLIFTON PARK
State
NY
ZIP
12065
Mailing
132 E. HILL ROAD, MIDDLEBURGH, NY 12122
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.502 D15

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 27, 2015
Abate by
Sep 2, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.502(d)(15):  Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee:  (a) Building Roof, on or about August 25, 2015 - the anchorage point for the personal fall arrest vertical lifeline system was not capable of supporting the requisite 5,000 pounds.
Recent events (1)
  • — Z (S) $1600

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Aug 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) Front of the building, on or about August 25, 2015 - the extension cord that was supplying power to the electric tools was missing the ground pin on the male end of the cord.
Recent events (1)
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Aug 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:  (a) Front of the building, on or about August 25, 2015 - the electrical cord for the DeWalt DWE575SB Type 1 circular saw, serial# 094841, had outer-jacket insulation damage.
Recent events (1)
  • — Z (O) $0

View Crew Contracting's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340876804.