EAST LIVERPOOL, OH —
OSHA Inspection: HERITAGE THERMAL SERVICES
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HERITAGE THERMAL SERVICES in 1250 ST. GEORGE ST., EAST LIVERPOOL, OH 43920 (NAICS 562211). OSHA activity number 340877430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HERITAGE THERMAL SERVICES
- Site address
- 1250 ST. GEORGE ST.
- City
- EAST LIVERPOOL
- State
- OH
- ZIP
- 43920
- Mailing
- 1250 ST. GEORGE ST., EAST LIVERPOOL, OH 43920
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562211
- Employees
- 180
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.120 P04
- Issued
- Feb 12, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $6,930 · Current $0 Reduced
General-duty citation text
29 CFR 1910.120(p)(4): The employer did not adequately develop and implement a decontamination procedure meeting the requirement of paragraph (k)(2)(iii) which requires that all employees leaving a contaminated area be appropriately decontaminated, and all contaminated clothing and equipment leaving the contaminated area be appropriately disposed of or decontaminated: a. On or about the night shift of August 18 and 19, 2015, an HTS service technician who was poisoned due to 4-chloroaniline resulting in methemoglobinemia by absorption and inhalation, was not properly decontaminated, which should have included flushing the eyes for at least 15 minutes and washing the body to remove potential contamination still on the body and this despite these requirements identified on the MSDS in the possession of HTS. b. On or about the night shift of August 18 and 19, 2015, an HTS employee was allowed to leave the worksite in an ambulance and proceed to the local hospital without the employee and his clothing being decontaminated or his potentially contaminated clothing removed before transport.
Recent events (3)
- — F (S) $0
- — C (S) $6930
- — Z (S) $6930
1910.132 A
- Issued
- Feb 12, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $13,860 · Current $27,720
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: On or before August 18, 2015, the employer failed to ensure that the employee was wearing the prescribed PPE. Instead the employee wore a Lakeland Pyrolon Apron when working with Waste Stream 117779-5 to perform the work. Heritage Thermal Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.132(a), which was contained in OSHA inspection number 281555, citation number 1, item number 1 and was affirmed as a final order on September 27, 2012, with respect to a workplace located at 1250 St. George St. E. Liverpool, Ohio 43920.
Recent events (3)
- — F (R) $27720
- — C (R) $13860
- — Z (R) $13860
1910.132 D01 I
- Issued
- Feb 12, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $13,860 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: On or before August 18, 2015, the employer failed to reassess and reselect appropriate personal protective equipment necessary to protect employees from the hazards associated with Waste Stream 117779-5, which include but are not limited to, p-chloroaniline. The employer failed to reassess the personal protective equipment when changing the p-chloroaniline from a solid to vapor during the steaming process. Appropriate personal protective equipment would include a full body suit that was impervious to p-chloroaniline and a self containing breathing apparatus (SCBA). Heritage Thermal Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.132(d)(1)(i), which was contained in OSHA inspection number 281555, citation number 1, item number 2 and was affirmed as a final order on September 27, 2012, with respect to a workplace located at 1250 St. George St. E. Liverpool, Ohio 43920.
Recent events (3)
- — F (R) $0
- — C (R) $13860
- — Z (R) $13860
1910.134 G02 I
- Issued
- Feb 12, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $13,860 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(g)(2)(i): The employer did not ensure that appropriate surveillance was maintained of work area conditions and degree of employee exposure or stress in order to reevaluate the continued effectiveness of the respirator: On or before August 18, 2015, the employer required an employee working with Waste Stream 117779-5 to perform the work while wearing 3M Full Facepiece Respirators (7800 Series) with combination cartridges. The employee was exposed to the chemicals in Waste Stream 117779-5, including but not limited to p-chloroaniline as evidenced by higher than normal methemoglobin levels found in the employee. The employee was using steam in the south bay to declog a discharge valve. The employees work area conditions and degree of employee exposure or stress were not reevaluated to assess the effectiveness of the respirators. Heritage Thermal Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(g)(2)(i), which was contained in OSHA inspection number 281555, citation number 1, item number 4 and was affirmed as a final order on September 27, 2012, with respect to a workplace located at 1250 St. George St. E. Liverpool, Ohio 43920.
Recent events (3)
- — F (R) $0
- — C (R) $13860
- — Z (R) $13860
1910.138 A
- Issued
- Feb 12, 2016
- Abate by
- Mar 4, 2016
- Penalty
- Initial $13,860 · Current $0 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: On or before August 18, 2015, the employer failed to require an employee working with Waste Stream 117779-5 to wear butyl gloves. The employee performed the work while wearing Stanzoil (style NL 34) neoprene gloves and nitrile gloves (style G-10). The gloves did not provide adequate protection from chemicals in Waste Stream 117779-5, including but not limited to p-chloroaniline as evidenced by higher than normal methemoglobin levels found in the employee. Heritage Thermal Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.138(a), which was contained in OSHA inspection number 281555, citation number 1, item number 5 and was affirmed as a final order on September 27, 2012, with respect to a workplace located at 1250 St. George St. E. Liverpool, Ohio 43920.
Recent events (3)
- — F (R) $0
- — C (R) $13860
- — Z (R) $13860
More inspections in this industry (NAICS 562211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340877430.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.