Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ASSEM-PAK, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ASSEM-PAK, INC. in 1649 CASTPA PLACE, VINELAND, NJ 08360 (NAICS 327213). OSHA activity number 340886985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Assem-Pak, INC. — free Get an email when a new federal OSHA severe-injury report for Assem-Pak, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ASSEM-PAK, INC.
Site address
1649 CASTPA PLACE
City
VINELAND
State
NJ
ZIP
08360
Mailing
1649 CASTPA PLACE, VINELAND, NJ 08360
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327213
Employees
110
Ownership type
A

13 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $6,300 · Current $4,725 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish the employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to crushing hazards:        a) Assem Pak, Inc. - Storage area: Employees were exposed to racks storing products two shelves high that had damaged horizontal, diagonal and vertical uprights in two sections (steel storage rack # 402), observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $4725
  • — Z (S) $6300

1910.178 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $3,600 · Current $2,700 Reduced
29 CFR 1910.178(g)(2):  Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:    a) Forklift charging area:  The facility did not protect the battery charging apparatuses from damage.  The charging cables on a Altech Electronics battery charger serial #1360, had damaged cords with exposed copper conduit, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3600

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $2,700 · Current $2,025 Reduced
29 CFR 1910.212(b):  Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) Assem-Pak, Inc., - Maintenance area near the Seals Department:  Top heavy machinery such as a Craftsman 8 Bench Grinder, Model # Not available, S/N not available was not bolted to the floor, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $4,500 · Current $4,725
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.    a)  Assem Pak, Inc.- Seals Department:  The minister B1-32 (machine #8) S/N B1-32-18091 had a missing guard for the chain and sprocket located approximately 6 ½ feet from the ground below, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $4725
  • — Z (S) $4500

1910.219 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)  Assem Pak Inc. - Seals area:  The Minister Press machine #6 had an unguarded belt and pulley, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.219 E01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    a)  Assem Pak Inc. - Seals area:  The Minister Press machine #6 had an unguarded belt and pulley, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 3 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $2,700 · Current $2,025 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Assem Pak Inc., - Sealer Department:  Power strips were used as permanent outlets to power Some electrical components of the minister press model #250-0280, observed on or about 08/17/2015.    b) Assem Pak Inc., - Warehouse area:  The Orion Wrap machine Model #L66/17,Serial #2003-0613480 was powered thru a power strip., observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.303 C03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.      a)  Assem Pak Inc., - Sealer Department:   Some electrical components of the minister press model #250-0280 had splip cables covered with masking tape, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.303 G01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Assem pak, Inc.- Maintenance tool room: Access to an electrical panels was obstructed by stored material and tool boxes. Observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.305 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $4,500 · Current $3,375 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) Assem-Pak - Sealer Area: The Minister machine #6 had a missing switch knock out next to the control panel, observed on or about 08/17/2015.    b) Assem-Pak - Rubber Area:  The Lin Cheng Machine #6 control panel had missing buttons, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $3375
  • — Z (S) $4500

1910.305 G02 III

Serious Gravity 5 3 instances 10 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) Assem Pak Inc.- Warehouse area:  The Orion Wrap machine Model #L66/17,Serial #2003-0613480 had a damaged strain relief , observed on or about 08/17/2015.    b) Assem Pak Inc.- Assembly area: The Sharklin Shrink Tunnel Machine Model I-6XLC, S/N T-95C107  had a damaged strain relief , observed on or about 08/17/2015.    c) Assem Pak Inc.- Rubber Department:  The Atom S.p.A. Die Cutter, Model #SE-25 serial #10002512-21 had a damaged strain relief, observed on or about 08/17/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.1200 F05 I

Other-than-serious 1 instance 5 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a) Assem-Pak Inc.,- Throughout the facility: The employer did not ensure that each container of hazardous chemical used in the workplace containing Alcohol, paint thinner, etc., was mark or labeled with its contents, on or about 08/17/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 10 exposed
Issued
Jan 14, 2016
Abate by
Feb 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Assem-Pak Inc.,- Throughout the facility: The employer had not provided information and training to employees on chemicals they used in the workplace such as but not limited to Alcohol, paint thinner, PLTEBD Cleaner, PLTA Thinner, Sapphire Ink MB Series, Loctite R220 Frekote Aqualine, etc., on or about 08/17/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340886985.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.