BOISE, ID —
OSHA Inspection: STOCK CONSTRUCTION MANAGEMENT SERVICES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STOCK CONSTRUCTION MANAGEMENT SERVICES, INC. in 8687 W OVERLAND ROAD, BOISE, ID 83709 (NAICS 236220). OSHA activity number 340888320.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STOCK CONSTRUCTION MANAGEMENT SERVICES, INC.
- Site address
- 8687 W OVERLAND ROAD
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 2990 WISE WAY, BOISE, ID 83716
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 21, 2015
- Abate by
- Sep 25, 2015
- Penalty
- Initial $918 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On or about August 31, 2015, and at times prior thereto, Stock Construction Management, as the controlling employer, did not ensure that a competent person made frequent inspections of the jobsite to identify and correct hazardous conditions to which its workers and subcontractor workers are exposed. The framing subcontractor was on its second day of sheathing the roof and this employer had not conducted an inspection to identify hazards including the lack of fall protection, extension ladder deficiencies, and impalement hazards from protruding bolts. NOTE: Abatement certification IS REQUIRED for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $918
5(a)(1)
- Issued
- Sep 21, 2015
- Abate by
- Sep 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from impalement hazards: a) From the time concrete work was completed to beyond August 31, 2015, multiple bolts extended approximately 3 inches vertical from the concrete along the west side of the building. Note 1: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B02 I
- Issued
- Sep 21, 2015
- Penalty
- Initial $1,530 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.501(b)(2)(i): Each employee who is constructing a leading edge 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems. a) On or about August 31, 2015, and at times prior thereto, two workers of the framing subcontractor installing wood sheathing on a nearly flat roof were not protected from fall hazards. The lower level of the roof was 14 to 15 feet high and the upper level was 17 to 18 feet high to the ground, concrete, equipment and materials below. Note 1: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Note 2: Abatement verification is NOT required for this item. Corrected during the inspection.
Recent events (2)
- — I (O) $1250
- — Z (S) $1530
1926.1053 B01
- Issued
- Sep 21, 2015
- Penalty
- Initial $1,530 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) West side of structure to access the lower roof level: The unsecured aluminum extension ladder used by the framing subcontractor employees extended only one rung above the lower of the roof levels. This ladder as used by workers involved in wood sheathing the roof. Note: Abatement certification is NOT required for this item. The ladders were observed corrected during the inspection.
Recent events (2)
- — I (O) $1250
- — Z (S) $1530
More inspections at Stock Construction Management Services, INC.
View Stock Construction Management Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340888320.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.