Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JACKSON-COOK LC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JACKSON-COOK LC in DOAK CAMPBELL STADIUM STADIUM DRIVE & PENSACOLA ST, TALLAHASSEE, FL 32310 (NAICS 236210). OSHA activity number 340892272.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jackson-Cook LC — free Get an email when a new federal OSHA severe-injury report for Jackson-Cook LC is published. One employer, no account, unsubscribe in one click.
Establishment
JACKSON-COOK LC
Site address
DOAK CAMPBELL STADIUM STADIUM DRIVE & PENSACOLA ST
City
TALLAHASSEE
State
FL
ZIP
32310
Mailing
P.O. BOX 2763, TALLAHASSEE, FL 32316
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
40
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 7 exposed
Issued
Oct 26, 2015
Penalty
Initial $4,900 · Current $2,450 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that Scissor Lift work platforms had defective slope limit alarms, and missing safety pins for guardrail systems.    a). On or about September 2, 2015, employees were operating a Genie lift brand elevated work platform, Model #GS3232, serial #848150RA with an inoperative slope alarm or limiter, exposing employees to a 30 foot fall hazard.    b). The top rail of the guardrails on the Genie Model GS3232, Serial #848150RA, lift did not have the manufacturer approved safety pins installed, exposing the employees to a 30 foot fall hazard.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.352 D

Other-than-serious 1 instance 4 exposed
Issued
Oct 26, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.352(d): Suitable fire extinguishing equipment shall be immediately available in the work area and shall be maintained in a state of readiness for instant use.    a). On or about September 23, 2015 Employees using Oxy/Acetylene torches to cut steel I-beams about 25 feet above the floor, and were not protected from fire or explosion hazards because no suitable fire extinguishing equipment was readily available to extinguish accidental fires.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 26, 2015
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) On or abut September 2, 2015, a temporary flexible cord used to energize portable hand grinders and Saws, and were not protected from electrical shock hazards by a path to ground that was permanent and continuous because the ground pin on the cord had been removed or broken off exposing employees to 110 Volt electrical shock hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2100

1926.502 D15 I

Deleted Serious Gravity 10 7 instances 7 exposed
Issued
Oct 26, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows: 29 CFR 1926.502(d)(15)(i): as part of a complete personal fall arrest system which maintains a safety factor of at least two;  a). On or about September 2, 2015 employees working at heights about 30 feet off the ground to remove existing steel I beams from a demolished passenger ramp, did not have the proper anchor points to attach personal fall protection systems while working at heights, exposing employees to 30 foot fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

View Jackson-Cook LC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340892272.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.