UTICA, NY —
OSHA Inspection: EV ROOFING & CONSTRUCTION SUPPLY CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EV ROOFING & CONSTRUCTION SUPPLY CORP. in UTICA MEMORIAL AUDITORIUM, 400 ORISKANY STREET, UTICA, NY 13502 (NAICS 238160). OSHA activity number 340893064.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EV ROOFING & CONSTRUCTION SUPPLY CORP.
- Site address
- UTICA MEMORIAL AUDITORIUM, 400 ORISKANY STREET
- City
- UTICA
- State
- NY
- ZIP
- 13502
- Mailing
- 35 SEYMOUR LANE, WESTMORELAND, NY 13490
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Oct 14, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) Southwest side of auditorium roof, on or about 8-28-15: Four employees were working outside a warning line, without fall protection or a safety monitor, exposing the employees to a fall hazard of 26 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.502 H01 V
- Issued
- Oct 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: a) Southwest side of auditorium roof, on or about 8-28-15: Four employees were working outside a warning line while the Safety Monitor was performing other duties and diverted his attention away from his safety monitoring duties.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at EV Roofing & Construction Supply Corp.
View EV Roofing & Construction Supply Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340893064.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.