Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMTECH SOUTHEAST LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMTECH SOUTHEAST LLC in 1142 STATE HWY 14, ELMORE, AL 36025 (NAICS 326199). OSHA activity number 340899343.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amtech Southeast LLC — free Get an email when a new federal OSHA severe-injury report for Amtech Southeast LLC is published. One employer, no account, unsubscribe in one click.
Site address
1142 STATE HWY 14
City
ELMORE
State
AL
ZIP
36025
Mailing
PO BOX 260, ELMORE, AL 36025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
47
Ownership type
A

3 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2015
Abate by
Dec 28, 2015
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  a) Welding area: On or about September 3, 2015 and at times prior thereto the employer exposed employees to fire hazards from oxygen cylinders and fuel gas (acetylene) cylinders which were stored unsecured near the entryway used by forklifts and employees. The cylinders could be knocked over by forklifts.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.253 B04 III

Repeat Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2015
Abate by
Dec 28, 2015
Penalty
Initial $25,000 · Current $25,000
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) Welding area: On or about September 3, 2015 and at times prior thereto the employer exposed employees to fire hazards in that an employee was allowed to work in the same area where oxygen cylinders and fuel gas (acetylene) cylinders were stored together without a noncombustible barrier as required by the standard.  Amtech Southeast LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.253(b)(4)(iii), which was contained in OSHA inspection number 941967, citation number 1, item number 7 and was affirmed as a final order on March 4, 2014, with respect to a workplace located at 1142 State Hwy 14, Elmore, Alabama, 36025.
Recent events (2)
  • — I (R) $25000
  • — Z (R) $25000

1910.1200 F06 II

Deleted Repeat Gravity 5 1 instance 5 exposed
Issued
Dec 17, 2015
Penalty
Initial $20,000 · Current $0 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical  (a)Building #10: On or about September 3, 2015 and at times prior thereto the employer exposed employees to chemical hazards from acetone by failing to ensure that each container of acetone in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof for hazard warnings.  Employees used unlabeled container with acetone for cleaning rollers and gloves. Acetone is extremely flammable liquid and vapor. Vapors may cause flash fire or explosion. Vapors may cause skin and eye irritation.  Amtech Southeast LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(f)(6)(ii), which was contained in OSHA inspection number 943870, citation number 1, item number 3 and was affirmed as a final order on March 4, 2014 with respect to a workplace located at 1142 State Hwy 14, Elmore, Alabama, 36025.
Recent events (2)
  • — I (R) $0
  • — Z (R) $20000

View Amtech Southeast LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340899343.