HOUSTON, TX —
OSHA Inspection: MANUFACTURED COMPONENT PARTS, LTD
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MANUFACTURED COMPONENT PARTS, LTD in 3001 WEST 11TH ST., HOUSTON, TX 77008 (NAICS 331210). OSHA activity number 340901057.
Where did this inspection happen?
- Establishment
- MANUFACTURED COMPONENT PARTS, LTD
- Site address
- 3001 WEST 11TH ST.
- City
- HOUSTON
- State
- TX
- ZIP
- 77008
- Mailing
- 3001 WEST 11TH ST., HOUSTON, TX 77008
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 30
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.110 F02 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: a) At the worksite where Liquefied Propane Gas cylinders were stored at a location exposed to physical damage by forklift traffic passing in close proximity.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) The employer failed to establish an adequate energy control program due to the lack of employee training, energy control procedures and periodic inspection ensuring employee safety against unexpected startup of machines or equipment.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) At the worksite where the procedures for the brake press in Bay 3 did not have procedures that were clear and specific outlining the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: a) At the worksite, overhead cranes located in Bay 1, Bay 2 - North and South, Bay 3 - North, Bay 4 - North and South and Bay 5 - North and South had not been inspected within the past 12 months.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.179 L03 III D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible: a) At the worksite where the crane pendant controls, including but not limited to Bay 1 and Bay 2, were not legible.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 N04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load at the beginning of each operator's shift: a) At the worksite where the crane's upper limit switch in Bay 1, Bay 2 North and Bay 3 North had not been tried out under no load at the beginning of each operator's shift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) At the worksite and in Bay 1, west wall, the circuit breaker box has openings that are unused and not closed.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 G02 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced: a) At the worksite and in Bay 5, a Hilti grinder was connected to a 25 foot long cord 12 gauge cord with an inadequate splice.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.178 L06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated to operate the powered industrial truck as required by this paragraph (l): a) At the worksite where the employer had not ensured that each powered industrial truck operator had been trained and evaluated.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 331210)
MUSCODA, WI—2026-07-10 00:00:00
SCOT INDUSTRIES, INC
BOISE, ID—2026-07-07 00:00:00
FARWEST STEEL CORPORATION
ANCHORAGE, AK—2026-07-01 00:00:00
STEELFAB
ANCHORAGE, AK—2026-07-01 00:00:00
STEELFAB
SOUTH LYON, MI—2026-06-25 00:00:00
MICHIGAN SEAMLESS TUBE LLC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340901057.