OSHA Inspection: MANUFACTURED COMPONENT PARTS, LTD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MANUFACTURED COMPONENT PARTS, LTD in 3001 WEST 11TH ST., HOUSTON, TX 77008 (NAICS 331210). OSHA activity number 340901057.

Watch Manufactured Component Parts, LTD — free Get an email when a new federal OSHA severe-injury report for Manufactured Component Parts, LTD is published. One employer, no account, unsubscribe in one click.
Site address
3001 WEST 11TH ST.
City
HOUSTON
State
TX
ZIP
77008
Mailing
3001 WEST 11TH ST., HOUSTON, TX 77008
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
30
Ownership type
A

9 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:  a)  At the worksite where Liquefied Propane Gas cylinders were stored at a location exposed to physical damage by forklift traffic passing in close proximity.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C01

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) The employer failed to establish an adequate energy control program due to the lack of employee training, energy control procedures and periodic inspection ensuring employee safety against unexpected startup of machines or equipment.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:  a) At the worksite where the procedures for the brake press in Bay 3 did not have procedures that were clear and specific  outlining the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J03

Serious Gravity 5 9 instances 20 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:   a)  At the worksite, overhead cranes located in Bay 1, Bay 2 - North and South, Bay 3 - North, Bay 4 - North and  South and Bay 5 - North and South had not been inspected within the past 12 months.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.179 L03 III D

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:  a) At the worksite where the crane pendant controls, including but not limited to Bay 1 and Bay 2, were not legible.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 N04 I

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load at the beginning of each operator's shift:  a) At the worksite where the crane's upper limit switch in Bay 1, Bay 2 North and Bay 3 North had not been tried out under no load at the beginning of each operator's shift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) At the worksite and in Bay 1, west wall, the circuit breaker box has openings that are unused and not closed.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:  a) At the worksite and in Bay 5, a Hilti grinder was connected to a 25 foot long cord 12 gauge cord with an inadequate splice.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.178 L06

Other-than-serious 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated to operate the powered industrial truck as required by this paragraph (l):  a) At the worksite where the employer had not ensured that each powered industrial truck operator had been trained and evaluated.