PHELPS, NY —
OSHA Inspection: MARSHALL EXTERIORS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MARSHALL EXTERIORS, LLC in 1907 ROUTE 96, PHELPS, NY 14532 (NAICS 238160). OSHA activity number 340911007.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARSHALL EXTERIORS, LLC
- Site address
- 1907 ROUTE 96
- City
- PHELPS
- State
- NY
- ZIP
- 14532
- Mailing
- 171 WEST SHORE BLVD, NEWARK, NY 14513
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 F07
- Issued
- Jan 7, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the jobsite, along the front porch of the building, on or about 9/8/15: Employees were using a ladder jack scaffold to access a section of the roof and to transfer roofing material to the roof where; the working platform was made with a section of extension ladder, not designed for this purpose and without the structural integrity in a horizontal placement to ensure the required load requirements, where the scaffold platform was placed so that the left side was in close proximity to supply power lines, and where no fall protection was provided for employees exposed to greater than a 10 foot fall to the ground. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.451 F01
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(1): Scaffold and/or scaffold components were loaded in excess of their maximum intended loads or rated capacities, whichever was less: a) At the jobsite, along the front porch of the building, on or about 9/8/15: Employees were using a ladder jack scaffold to access a section of the roof and to transfer roofing material to the roof where the working platform was made with a section of extension ladder, not designed for this purpose and without the structural integrity in a horizontal placement to ensure the required load capacity. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01 I
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) At the jobsite, along the front porch of the building, on or about 9/8/15: Employees were using a ladder jack scaffold to access a section of the roof and to transfer roofing material to the roof where the working platform was made with a section of extension ladder, where a length of plywood was placed over the rungs to provide a walkable surface, and where that plywood did not extend over the entire length of the platform. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F06
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) At the jobsite, along the front porch of the building, on or about 9/8/15: Employees were using a ladder jack scaffold to access a section of the roof and to transfer roofing material to the roof where the working platform was made with a section of extension ladder, where that ladder was placed horizontally and where the end to the East of the placement was within 1 foot of where the supply power lines were connected to the residence. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) At the jobsite, along the front porch of the building, on or about 9/8/15: Employees were using a ladder jack scaffold to access a section of the roof and to transfer roofing material to the roof where the working platform was placed approximately 3 feet above the surface of the 4:12 pitch porch roof. The width of the scaffold system would have allowed for only 2 feet or less of surface to prevent a subsequent fall of 10 feet to ground. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 9/8/15: Employees were stripping a 4:12 section of roof, with a measured 17.5 foot ground to eave height, without fall protection of any kind. This condition resulted in an employee falling 17.5 feet from the roof to the ground. b) At the jobsite, on the roof, on or about 9/8/15: Employees were working on a 4:12 section of roof, with a measured 17.5 foot ground to eave height, without adequate fall protection. Lifelines were observed on the roof without anchor points. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Jan 7, 2016
- Abate by
- Jan 13, 2016
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, on the porch roof, on or about 9/8/15: Employees were using a portable ladder to access a 4:12 porch roof, with an approximate 10 foot ground to eave height, where the ladder did not extend at least 3 feet above the landing being accessed. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
More inspections at Marshall Exteriors, LLC