Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: V.T.M.C. CORPORATION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of V.T.M.C. CORPORATION in 12106 EASTEX FWY SERVICE RD., HOUSTON, TX 77039 (NAICS 236220). OSHA activity number 340911494.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V.T.M.C. Corporation — free Get an email when a new federal OSHA severe-injury report for V.T.M.C. Corporation is published. One employer, no account, unsubscribe in one click.
Site address
12106 EASTEX FWY SERVICE RD.
City
HOUSTON
State
TX
ZIP
77039
Mailing
10020 JENSEN DR., HOUSTON, TX 77093
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.404 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $7,000 · Current $1,000 Reduced
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity:    On or about September 10, 2015, in the NW corner of the building, employees were exposed to an electrical shock hazard when operating electrical saws and drills without a grounded conductor attached to a terminal or lead so as to prevent reverse polarity.
Recent events (3)
  • — R (S) $1000
  • — C (S) $7000
  • — Z (S) $7000

1926.404 B01 I

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $7,000 · Current $1,000 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.     On or about September 10, 2015, in the NW corner of the building, employees were exposed to an electrical shock hazard when operating electrical saws and drills without ground fault circuit interrupters or an assured grounding program.
Recent events (3)
  • — R (S) $1000
  • — C (S) $7000
  • — Z (S) $7000

1926.404 F06

Serious Gravity 10 3 instances 4 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $7,000 · Current $1,000 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:     On or about September 10, 2015, throughout the worksite:    a. Employees throughout the facility were exposed to an electrical shock hazard when operating electrical equipment connected to a temporary power pole without the path to ground being permanent and continuous.     b. Employees in the kitchen area were exposed to an electrical shock hazard when using a temporary light connected to an electrical cord without the path to ground being permanent and continuous.
Recent events (3)
  • — R (S) $1000
  • — C (S) $7000
  • — Z (S) $7000

1926.405 D

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $5,000 · Current $500 Reduced
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front:     On or about September 10, 2015, in the east side parking area, employees were exposed to an electrical shock hazard when connecting electrical cords to outlets on a temporary power pole without the circuit breaker panel having a dead front.
Recent events (3)
  • — R (S) $500
  • — C (S) $5000
  • — Z (S) $5000

1926.405 G02 III

Serious Gravity 10 5 instances 4 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $7,000 · Current $1,000 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    On or about September 10, 2015, and times prior thereto:    a. Employees in the NW corner of the building were exposed to electrical shock hazards when using an electrical cord to operate electrical equipment without the cord being free of splices.    b. Employees in the kitchen area of the building were exposed to electrical shock hazards when using an electrical cord to supply power to temporary lighting without the cord being free of splices.    c. Employees in the hallway east of the kitchen were exposed to electrical shock hazards when using an electrical cord to operate equipment without the cord being free of splices.    d. Employees in the east end of the building were exposed to electrical shock hazards when operating a Ridgid miter saw, Model   R4121, without the power cord being free of splices.    e. Employees in the east end of the building were exposed to electrical shock hazards when operating a Makita circular saw, Model 5007A, without the power cord being free of splices.
Recent events (3)
  • — R (S) $1000
  • — C (S) $7000
  • — Z (S) $7000

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:   On or about September 10, 2015, throughout the facility, employees were exposed to electrical shock hazards when operating electrical equipment without each employee being instructed in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

1904.39 A01

Other-than-serious 1 instance 4 exposed
Issued
Nov 23, 2015
Abate by
Dec 11, 2015
Penalty
Initial $2,000 · Current $500 Reduced
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident.    On or about September 10, 2015, at approximately 2:30 pm, an employee was fatally injured when installing plumbing at a construction worksite and the employer did not report the fatality within 8 hours.
Recent events (3)
  • — R (O) $500
  • — C (O) $2000
  • — Z (O) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340911494.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.