Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ONESOURCE HARD SURFACES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ONESOURCE HARD SURFACES, LLC in 523 HILL ROAD, DALTON, GA 30721 (NAICS 323120). OSHA activity number 340913391.

Watch Onesource Hard Surfaces, LLC — free Get an email when a new federal OSHA severe-injury report for Onesource Hard Surfaces, LLC is published. One employer, no account, unsubscribe in one click.
Site address
523 HILL ROAD
City
DALTON
State
GA
ZIP
30721
Mailing
523 HILL ROAD, DALTON, GA 30721
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323120
Employees
50
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4200.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    (a) In the production area, specific procedures for shutting down, isolating, and securing energy sources were not developed and utilized when servicing and maintaining equipment such as, but not limited to, panel saws and chop saws, exposing the employees to electrical and amputation hazards.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.147 C05 I

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4200.00 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    (a) In the production area, saw operators responsible for performing saw blade changes on panel and chop saws were not provided with lockout and tagout devices, exposing the employees to an amputation hazard.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.147 C07 I

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:  (a) In the production area, the employer did not provide training to authorized and affected employees to ensure that the employees understood the purpose and the function of the Company's energy control procedures when performing saw blade changes on panel and chop saws. The employees were exposed to electrical and amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $3000.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     (a) In the production department, panel saw operators working on Saw-2 were using compressed air to clean wood chips and debris from the panel saw. The air nozzle being used was not equipped with a diffuser or a safety pressure reducer tip. Air pressure of 105 psi was being released from the nozzle, exposing the employee to a struck-by hazard and air embolism.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000