On , OSHA opened an unprogrammed Other safety inspection of MARTINEZ MASONRY, INC. in 157 HEATON PARK DRIVE, ATLANTA, GA 30307 (NAICS 238140). OSHA activity number 340916428.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Martinez Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Martinez Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
157 HEATON PARK DRIVE
City
ATLANTA
State
GA
ZIP
30307
Mailing
2629 TUCKER MILL ROAD SW, CONYERS, GA 30094
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 25, 2015
Penalty
Initial $3,080 · Current $2,002 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  On or about 9/11/15 on the site at 157 Heaton Park Drive, in Atlanta, GA: Employees were exposed to fall hazards while using the frame and cross braces to access and egress the scaffold system with a hook-on-attachment ladder that was not installed completely installed.
Recent events (2)
  • — I (S) $2002
  • — Z (S) $3080

1926.451 E02 IV

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(2)(iv): Hook-on and attachable ladders was not specifically designed for use with the type of scaffold used;  On or about 9/11/15 on the site at 157 Heaton Park Drive, in Atlanta, GA: Employees were exposed to fall hazards while using a ladder that was not completely installed as specifically designed for employees to safely access and egress the scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E09 II

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(9)(ii): Hook-on or attachable ladders was not installed as soon as scaffold erection has progressed to a point that permits safe installation and use.  On or about 9/11/15 on the site at 157 Heaton Park Drive, in Atlanta, GA: The employer failed to install the hook-on-attachable ladders to the scaffold system as the employees progressed to safely access the ladder while in use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 25, 2015
Abate by
Oct 1, 2015
Penalty
Initial $3,080 · Current $1,994 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about 9/11/15 on the roof of the building at 157 Heaton Park Drive in Atlanta, GA: Employee was exposed to a fall hazard of up to 10 feet while cleaning material from the roof and not protected from a fall hazard.
Recent events (2)
  • — I (S) $1994
  • — Z (S) $3080

View Martinez Masonry, INC.'s full OSHA safety record →