MELISSA, TX —
OSHA Inspection: FELIPE BEJERANO
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FELIPE BEJERANO in 3401 SEQUOIA LANE, MELISSA, TX 75454 (NAICS 238330). OSHA activity number 340917038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FELIPE BEJERANO
- Site address
- 3401 SEQUOIA LANE
- City
- MELISSA
- State
- TX
- ZIP
- 75454
- Mailing
- 2501 WEBB CHAPEL EXTENSION APT. 1105, DALLAS, TX 75220
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238330
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 F06
- Issued
- Feb 26, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Galaxy Omega Floor Sander: The floor sander was being operated by an employee and was energized but did not have a grounding conductor. This condition exposed the employee to shock and/or electrocution hazards.
Recent events (1)
- — Z (S) $2800
1926.405 G01 II
- Issued
- Feb 26, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.405(g)(1)(ii): Flexible cord was not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]: a) Galaxy Omega Floor Sander: The floor sander was being operated by an employee and was energized by having the bare conductors of the flexible cord placed into the receptacle which exposed employees to shock, electrocution and/or fire hazards.
Recent events (1)
- — Z (S) $2800
More inspections at Felipe Bejerano
View Felipe Bejerano's full OSHA safety record →
More inspections in this industry (NAICS 238330)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340917038.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.