COLUMBUS, OH —
OSHA Inspection: MIDWEST EQUIPMENT SALES, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MIDWEST EQUIPMENT SALES, LLC. in 777 MANOR PARK DRIVE, COLUMBUS, OH 43228 (NAICS 493110). OSHA activity number 340917582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDWEST EQUIPMENT SALES, LLC.
- Site address
- 777 MANOR PARK DRIVE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 777 MANOR PARK DRIVE, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 6
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.132 D01
- Issued
- Dec 17, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: a. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not conduct a hazard assessment of servicing forklift batteries in order to determine the personal protective equipment needed to protect employees from exposure to battery acid.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.151 C
- Issued
- Dec 17, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. [63 FR 33450, June 18, 1998] a. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not provide an emergency eye wash station for employees exposed to battery acid while servicing the forklift batteries.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.219 D01
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a. Located at 777 Manor Park Drive in Columbus, Ohio: an air compressor manufactured by AB Air Compressor Systems was used to supply compressed air for two tire machines which were located near the south wall of the building. Employees operating the control switch and pressure valve were exposed to ingoing nip point hazards due to unguarded pulleys on the compressor.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.253 B02 II
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards. a. Located at 777 Manor Park Drive in Columbus, Ohio: ten oxygen and acetylene compressed gas cylinders were stored in the maintenance shop. The cylinders were not secured from being knocked over, exposing employees to a struck by hazard.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.253 B02 IV
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use. a. Located at 777 Manor Park Drive in Columbus, Ohio: an oxygen and acetylene torch cart was stored in the maintenance shop without removing the regulators from the cylinders, exposing employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a. Located at 777 Manor Park Drive in Columbus, Ohio: six oxygen cylinders were stored beside four acetylene cylinders in the maintenance shop, exposing employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a. Located at 777 Manor Park Drive in Columbus, Ohio: employees were exposed to energized electrical wires due to a missing box cover located at column I-12. b. Located at 777 Manor Park Drive in Columbus, Ohio: employees were exposed to energized electrical wires due to a missing box cover located at column F-3. c. Located at 777 Manor Park Drive in Columbus, Ohio: employees were exposed to energized electrical wires due to a missing box cover located at column G-3. d. Located at 777 Manor Park Drive in Columbus, Ohio: the flexible cord used to wire a 480 volt air compressor located on the south wall of the warehouse had unprotected wire nut joints, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.305 B01 II
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a. Located at 777 Manor Park Drive in Columbus, Ohio: there were unused openings on the side of the 120/208 volt, 3 phase, electrical panel, located at column I-14, exposing employees to an electrical flash hazard. b. Located at 777 Manor Park Drive in Columbus, Ohio: there were multiple unused breaker openings in the dead front cover of the 277/480 volt, 3 phase, panel located at column F-8, exposing employees to an electrical shock and flash hazard.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.305 D02
- Issued
- Dec 17, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. a. Located at 777 Manor Park Drive in Columbus, Ohio: a dead front cover was not replaced on the 120/208 volt, 3 phase electrical panel located at column I-14, exposing employees to an electrical shock and flash hazard. b. Located at 777 Manor Park Drive in Columbus, Ohio: a dead front cover was not replaced on the 120/208 volt, 3 phase electrical panel located at column F-7, exposing employees to an electrical shock and flash hazard.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.332 B01
- Issued
- Dec 17, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. a. Located at 777 Manor Park Drive in Columbus, Ohio: employees performing work in the warehouse were not trained on electrical shock, arc flash, and arc blast hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.335 B
- Issued
- Dec 17, 2015
- Abate by
- Dec 29, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.335(b): Alerting techniques. The following alerting techniques shall be used to warn and protect employees from hazards which could cause injury due to electric shock, burns, or failure of electric equipment parts: a. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not provide a means to warn employees of electrical shock and arc flash hazards at an unprotected 120/208 volt, 3 phase, electrical panel located at column I-14. b. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not provide a means to warn employees of electrical shock and arc flash hazards at an unprotected 120/208 volt, 3 phase, electrical panel located at column F-7. c. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not provide a means to warn employees of electrical shock and arc flash hazards at an unprotected 277/480 volt, 3 phase, electrical panel located at column F-8.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.178 L01 I
- Issued
- Dec 17, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a. Located at 777 Manor Park Drive in Columbus, Ohio: the employer did not ensure that employees working in the warehouse were properly trained and certified on the safe use of the forklifts prior to allowing them to operate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Midwest Equipment Sales, LLC.
View Midwest Equipment Sales, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340917582.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.