Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HERITAGE SLEEP PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HERITAGE SLEEP PRODUCTS in 161 GRAND VALLEY AVE, ORWELL, OH 44076 (NAICS 337910). OSHA activity number 340927185.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Heritage Sleep Products — free Get an email when a new federal OSHA severe-injury report for Heritage Sleep Products is published. One employer, no account, unsubscribe in one click.
Site address
161 GRAND VALLEY AVE
City
ORWELL
State
OH
ZIP
44076
Mailing
161 GRAND VALLEY AVE, ORWELL, OH 44076
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337910
Employees
22
Ownership type
A

6 citations on file for this inspection.

1903.19 D01

Other-than-serious 2 instances 2 exposed
Issued
May 23, 2016
Abate by
Jun 25, 2016
Penalty
Initial $400 · Current $400
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  At the time of the inspection, the employer failed to establish a lockout/tagout program for employees who were tasked with changing the needles and performing maintenance of the boarder quilter and the panel quilter.
Recent events (1)
  • — Z (O) $400

1910.147 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 29, 2016
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    At the time of inspection, the employer failed to establish a lockout/tagout program, for employees who were tasked with changing the needles, and performing maintenance of the boarder quilter, and the panel quilter.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.212 A01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Dec 8, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  At the time of inspection, the employer failed to provide adequate machine guarding to the following:  The Boarder quilter and the Panel quilter were equipped with partial light curtains. There was a gap between the light curtains that was greater than 1 1/4 inches in width. The distance from light curtain to the needles and moving parts was about 15 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.219 C02

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Dec 8, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.219(c)(2): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafing completely:    At the time of inspection, the employer failed to provide adequate machine guarding in that the Panel quilter's door was open which exposed the rotating shaft.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.219 F03

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Dec 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above the floor or platform were not enclosed:  At the time of inspection, the employer failed to provide adequate machine guarding in that the Panel quilter's door was open which exposed the sprocket and chain.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 18, 2015
Abate by
Dec 8, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    At the time of inspection, the employer failed to ensure that the wiring of the light fixture, inside the Boarder panel quilter, was wired in accordance with instructions. The wiring was connected with wire nuts and plugged into a standard 110v outlet.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340927185.