Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROMANOFF ELECTRIC RESIDENTIAL CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ROMANOFF ELECTRIC RESIDENTIAL CORP. in 4303 TRUEMAN BLVD, HILLIARD, OH 43026 (NAICS 238210). OSHA activity number 340928753.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Romanoff Electric Residential Corp. — free Get an email when a new federal OSHA severe-injury report for Romanoff Electric Residential Corp. is published. One employer, no account, unsubscribe in one click.
Site address
4303 TRUEMAN BLVD
City
HILLIARD
State
OH
ZIP
43026
Mailing
1288 RESEARCH ROAD, GAHANNA, OH 43230
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
110
Ownership type
A

2 citations on file for this inspection.

1926.405 B01

Serious Gravity 10 2 instances 7 exposed
Issued
Oct 14, 2015
Abate by
Oct 28, 2015
Penalty
Initial $6,930 · Current $3,465 Reduced
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.  a.  On the first floor of the Bistro Area B where the temporary electric was set up, there was one unused opening which measured 3 inches in diameter on the main panel connected to the generator thereby exposing employees to an electrical hazard.  b.  On the first floor of the Bistro Area B where the temporary electric was set up, there was one unused opening which measured 3/4 inches in diameter on the main panel connected to the generator thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6930

1926.405 G02 III

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 14, 2015
Penalty
Initial $4,950 · Current $2,475 Reduced
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.  a.  On the first floor Area A-1, the electrical contractor spliced two pieces of romex together just below the receptacle and covered partially with electrical tape thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $4950

View Romanoff Electric Residential Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340928753.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.