MIDDLETON, MA —
OSHA Inspection: NEWCASTLE SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEWCASTLE SYSTEMS, INC. in 15B SYLVAN STREET, MIDDLETON, MA 01949 (NAICS 337124). OSHA activity number 340929496.
Where did this inspection happen?
- Establishment
- NEWCASTLE SYSTEMS, INC.
- Site address
- 15B SYLVAN STREET
- City
- MIDDLETON
- State
- MA
- ZIP
- 01949
- Mailing
- 15B SYLVAN STREET, MIDDLETON, MA 01949
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337124
- Employees
- 15
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.38 B
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: Location: Facility On or about 9/18/15, the employer did not have a written emergency action plan at the workplace and was not available for employees to review.
Recent events (2)
- — I (S) $500
- — Z (S) $1200
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: Location: Warehouse On or about 9/4/15, an employee without fall protection stood on the forks and was raised in the air by the Yale high lift powered pallet jack to access the top shelf of the storage racks and was exposed to fall hazards of up to 12-feet, 3.5-inches.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: Location: Warehouse On or about 9/4/15, the employer did not assess and certify the workplace of hazards for the employee that stands on the forks of the Yale high lift powered pallet jack without fall protection, to access the top shelf of the storage racks and was exposed to fall hazards of up to 12-feet, 3.5-inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 M03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(m)(3): A safe place to ride was not provided where riding a powered industrial truck(s) was authorized Location: Warehouse On or about 9/4/15, the employer allowed an employee to ride the forks of the powered pallet jack and was exposed to fall hazards of up to 12-feet, 3.5-inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. Location: Facility On or about 9/18/15, the employer did not evaluate powered industrial truck operators prior to being permitted to operate powered industrial trucks.
Recent events (2)
- — I (S) $1200
- — Z (S) $2800
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Location: NB Product Cell On or about 9/18/15, the employer connected a Wiremold 15-amp relocatable power strip plugged into a three-way extension cord to another extension cord that supplied power to a heat gun, DeWalt battery charger, and a 1/2" DeWalt impact gun exposing workers to electric shock and fire hazards. Location: PC Product Cell On or about 9/18/15, the employer utilized four inadequate drop down outlet boxes, one of which powered an air compressor, power tools, battery chargers, and fans, exposing workers to electric shock and fire hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.304 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: Location: NB Product Cell On or about 9/18/15, the employer overloaded a Wiremold 15-amp relocatable power strip plugged into a three-way extension cord to another extension cord that supplied power to a DeWalt battery charger, a DeWalt impact gun, and a fan exposing workers to electric shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners: Location: NB Product Cell On or about 9/18/15, the employer daisy chained two extension cords plugged together to supply power to a heat gun and relocatable power strip supplying power to a fan, 1/2 inch DeWalt impact gun, DeWalt battery charger exposing employees to electric shock and fire hazards. Location: PC Product Cell On or about 9/18/15, the employer used an extension cord as permanent wiring to charge a Wesco stacker exposing employees to electric shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $200.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Location: Warehouse On or about 9/18/15, the employer did not have the ABC rated fire extinguisher subjected to an annual maintenance check.
Recent events (2)
- — I (O) $200
- — Z (O) $400
More inspections at NEWCASTLE SYSTEMS, INC.
MIDDLETON, MA—2015-10-19 00:00:00
NEWCASTLE SYSTEMS, INC.
View NEWCASTLE SYSTEMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337124)
SEATTLE, WA—2026-07-13 00:00:00
WA317992052 - OUT OF ROUND DESIGN LLC
OCALA, FL—2026-06-04 00:00:00
ADMIRAL FURNITURE, LLC
DULUTH, MN—2026-05-12 00:00:00
111228 - ALUMINUM CABINET COMPANY INC
CHICAGO, IL—2026-04-17 00:00:00
EDSAL MANUFACTURING COMPANY, LLC
PUNXSUTAWNEY, PA—2026-01-27 00:00:00
WINDWARD OUTDOOR, LLC
More inspections in MA
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
ATTLEBORO, MA—2026-07-16 00:00:00
R M PACELLA INC
LYNN, MA—2026-07-16 00:00:00
A.M.B. IRON LLC
NEWTON, MA—2026-07-16 00:00:00
A&S CARPENTRY, INC.
BELLINGHAM, MA—2026-07-16 00:00:00
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
Source