Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PLUMB RITE INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PLUMB RITE INC. in 50 HEATHERDALE ROAD, ARDSLEY, NY 10502 (NAICS 238220). OSHA activity number 340940261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Plumb Rite INC. — free Get an email when a new federal OSHA severe-injury report for Plumb Rite INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PLUMB RITE INC.
Site address
50 HEATHERDALE ROAD
City
ARDSLEY
State
NY
ZIP
10502
Mailing
107 WOOD AVENUE, ARDSLEY, NY 10502
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
5
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 27, 2015
Abate by
Dec 23, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
OSH ACT of 1970 Section (5)(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being caught in rotating parts.    Location: 50 Heatherdale Road, Ardsley, NY 10502      On or about 7-31-2015    a) The Ridgid model 300 pipe threading machine did not have a momentary contact device that would cause the machine to stop in an emergency such as if the employees clothing became entangled around rotating machine parts or the rotating pipe.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.403 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    On or about 7/31/15    Location: 50 Heatherdale Road, Ardsley, NY 10501    a) A 120 volt duplex metal outlet "J" box designed and listed to be used as part of the permanent wiring of a structure and attached to a structural member was used as a distribution point at the end of an extension cord which is a use not in accordance with its listing and certification.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.404 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2015
Abate by
Dec 23, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:    On or about 7/31/15    Location: 50 Heatherdale Road, Ardsley, NY 10502    a) 120 Volt 20 Amp receptacles on a three-wire, dual voltage Generac GP5500 120v/240v portable generator rated at 5.5 kW  were not be protected with ground-fault circuit interrupters.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.405 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    On or about 7/31/15    Location: 50 Heatherdale Road, Ardsley, NY 10502    a) A short, approximately 8 inch long, male plug end of an orange extension cord was spliced to a black extension cord and used to power 120 volt hand tools.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.416 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  On or about 7/31/15  Location: 50 Heatherdale Road, Ardsley, NY 10502  a) The outer insulation on the male plug end of an extension cord was cut, approximately 1 inch from the plug, exposing the insulated inner conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Plumb Rite INC.'s full OSHA safety record →