Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLUMBIA WEST VIRGINIA CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COLUMBIA WEST VIRGINIA CORPORATION in 242 COLUMBIA FOREST PRODUCTS ROAD, CRAIGSVILLE, WV 26205 (NAICS 321211). OSHA activity number 340943208.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Columbia West Virginia Corporation — free Get an email when a new federal OSHA severe-injury report for Columbia West Virginia Corporation is published. One employer, no account, unsubscribe in one click.
Site address
242 COLUMBIA FOREST PRODUCTS ROAD
City
CRAIGSVILLE
State
WV
ZIP
26205
Mailing
P.O. BOX 160, CRAIGSVILLE, WV 26205
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321211
Employees
213
Ownership type
A

6 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2016
Abate by
Feb 11, 2016
Penalty
Initial $6,600 · Current $4,950 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered (as referenced by 1910.252(b)(3)):  (a) Shop Area:  On or about September 24, 2015 and times prior personal protective equipment, such as, but not limited to, a welding jacket and welding cap, were not worn to protect exposed skin during welding operations.
Recent events (2)
  • — I (S) $4950
  • — Z (S) $6600

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  (a) Shop Area:  On or about September 24, 2015 and times prior, the employer did not assess the maintenance department to determine the need for appropriate personal protective equipment during welding operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2016
Abate by
Feb 19, 2016
Penalty
Initial $4,400 · Current $3,300 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Maintenance Department:  On or about September 24, 2015 and times prior, employees perform maintenance on vehicles such as forklifts however, a procedure to ensure that all energy sources were isolated was not developed.
Recent events (2)
  • — I (S) $3300
  • — Z (S) $4400

1910.252 A02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 1, 2016
Abate by
Feb 19, 2016
Penalty
Initial $4,400 · Current $3,300 Reduced
29 CFR 1910.252(a)(2)(iv): Cutting or welding was permitted in areas before the areas were inspected by the individual responsible for authorizing cutting and welding operations:  (a) Maintenance Shop:  On or about September 24, 2015 and times prior, an employee was permitted to weld in an area where hydraulic fluid, a known flammable was leaking prior to the maintenance shop area being inspected and approved for the task by the team lead.
Recent events (2)
  • — I (S) $3300
  • — Z (S) $4400

1910.252 A03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which were subjected to heat, might produce flammable or toxic vapors:  (a) Shop Area:  On or about September 24, 2015 and times prior, employees were permitted to perform welding operations that contain liquid and/or pressure, such as, 6ft. by 3/4 inch and 1mm thick Linde forklift hydraulic lines, that had not been cleared and cleaned of hydraulic fluid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 1, 2016
Abate by
Feb 11, 2016
Penalty
Initial $4,400 · Current $3,300 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:  (a) Maintenance Shop:  On or about September 24, 2015 and times prior, an employee used a Lincoln Electric, Idealarc CV-300 welder with 300 amp, 230/460 volt, 3 phase power, that had damaged insulation and exposed copper at the work lead clamp, used to connect the work lead cable to the work piece.
Recent events (2)
  • — I (S) $3300
  • — Z (S) $4400

View Columbia West Virginia Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340943208.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.