Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KENNY HALSDORF CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KENNY HALSDORF CONSTRUCTION LLC in STATE ROUTE 49 AND COUNTY ROUTE 37, CENTRAL SQUARE, NY 13036 (NAICS 238160). OSHA activity number 340944065.

Watch Kenny Halsdorf Construction LLC — free Get an email when a new federal OSHA severe-injury report for Kenny Halsdorf Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
STATE ROUTE 49 AND COUNTY ROUTE 37
City
CENTRAL SQUARE
State
NY
ZIP
13036
Mailing
321 COUNTY ROUTE 33, CENTRAL SQUARE, NY 13036
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  At the jobsite, on a porch roof, on or about 9/24/15:  A worker was performing roofing work on a multi slope porch roof (4:12 and 6:12) with an approximate ground to eave height of 10 feet, without fall protection of any kind.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  At the jobsite, on a porch roof, on or about 9/24/15:  A worker gained access to a multi slope porch roof (4:12 and 6:12) with an approximate ground to eave height of 10 feet, with an extension ladder and where that ladder did not extend at least 3 feet above the upper landing.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340944065.