OSHA Inspection: ENGINEERED STRUCTURES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENGINEERED STRUCTURES, INC. in 911 NORTH MERIDIAN ROAD, MERIDIAN, ID 83642 (NAICS 236220). OSHA activity number 340944909.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Engineered Structures, INC. — free Get an email when a new federal OSHA severe-injury report for Engineered Structures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
911 NORTH MERIDIAN ROAD
City
MERIDIAN
State
ID
ZIP
83642
Mailing
3330 E. LOUISE DR. STE. 300, MERIDIAN, ID 83642
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.651 I03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 27, 2015
Abate by
Nov 2, 2015
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements and appurtenant structure were undermined without a support system or another method of protection provided to protect employees from the possible collapse of such structures:    a) Jobsite: On September 24, 2015 the controlling employer Engineered Structures, Inc., did not ensure its sub-contractor protected their employees while working in a trench where the walls had fallen away, leaving unsupported pavement overhead.     Note) Abatement certification AND documentation are required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1926.651 J02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 27, 2015
Abate by
Nov 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations:  a) Jobsite: On September 24, 2015 the controlling employer Engineered Structures, Inc., did not ensure that its sub-contractor protected their employee while working in a trench where the spoil piles were not placed at least 2 feet back from the edge of a trench.   Note) Abatement certification AND documentation are required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 27, 2015
Abate by
Nov 2, 2015
Penalty
Initial $0 · Current $7,000
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift:     a) Jobsite: On September 24, 2015 the controlling employer, Engineered Structures, Inc., did not ensure that its sub-contractor protected their employees.  The sub-contractor did not have a competent person to conduct an inspection prior to the start of their work and as needed throughout the trenching and employee work activities in the trench.          Note) The competent person definition applicable to this subpart means one who is capable of identifying existing and predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.     Note) Abatement certification AND documentation are required for this item.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $0

1926.652 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Oct 27, 2015
Abate by
Nov 2, 2015
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    a) Jobsite: On September 24, 2015 the controlling employer Engineered Structures, Inc., did not ensure that its sub-contractor protected their employee while work was done in a trench without a cave-in protective system in place.  The trench ranged from 6 and a half feet to just over 7 and a half feet deep.         Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3825

View Engineered Structures, INC.'s full OSHA safety record →