OSHA Inspection: VALLEY STORM SHELTERS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VALLEY STORM SHELTERS, LLC in 14628 US HIGHWAY 72, SCOTTSBORO, AL 35768 (NAICS 332999). OSHA activity number 340946326.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valley Storm Shelters, LLC — free Get an email when a new federal OSHA severe-injury report for Valley Storm Shelters, LLC is published. One employer, no account, unsubscribe in one click.
Site address
14628 US HIGHWAY 72
City
SCOTTSBORO
State
AL
ZIP
35768
Mailing
14628 US HIGHWAY 72, SCOTTSBORO, AL 35768
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
8
Ownership type
A

8 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2016
Abate by
Feb 14, 2016
Penalty
Initial $1,600 · Current $960 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    a) On or about 09/23/2015 - Fabrication area, an employee conducting welding and fabricating work was exposed to occupational noise at 200.1% of the allowable 8-hour time-weighted average of 85 dBA or an equivalent sound level of 95.0 dBA. The sampling was performed for 435 minutes on 09/22/2015. Zero exposure was assumed for the remainder of the shift.    (b) On or about 09/22/2015 - Fabrication area, an employee conducting welding and fabricating work was exposed to occupational noise at 85.9% of the allowable 8-hour time-weighted average of 85 dBA or an equivalent sound level of 89.9 dBA. The sampling was performed for 430 minutes on 09/23/2015. Zero exposure was assumed for the remainder of the shift.    (c) On or about 09/22/2015 - Fabrication area, an employee conducting welding and fabricating work was exposed to occupational noise at 92.7% of the allowable 8-hour time-weighted average of 85 dBA or an equivalent sound level of 89.4 dBA. The sampling was performed for 426 minutes on 09/23/2015. Zero exposure was assumed for the remainder of the shift.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.107 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Mar 16, 2016
Penalty
Initial $1,200 · Current $720 Reduced

Hazardous substances 25909685T306

29 CFR 1910.107(b)(1): Spray booth(s) were not substantially constructed of steel, or of concrete or masonry:    a) On or about 09/22/15 - Main plant, the spray booth was constructed of wood.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.107 G02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Mar 16, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 25909685T306

29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:    a) On or about 09/22/15 - Main plant, combustible residues had been allowed to accumulate in the spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B05 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Mar 16, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 25909685T306

29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a) On or about 09/22/15 - Main plant, automatic sprinklers were not installed in the spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C05

Serious Gravity 1 3 instances 1 exposed
Issued
Jan 12, 2016
Abate by
Mar 16, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 25909685T306

29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s):    a) On or about 09/22/15 - Main plant, spray booth, four 120VAC electrical wall outlets on the south wall were not approved for use in hazardous locations.    b) On or about 09/22/15 - Main plant, spray booth, a 240/480 VAC electrical wall switch on the south wall was not approved for use in hazardous locations.    c) On or about 09/22/15 - Main plant, spray booth, two 120 VAC electrical fans used inside the booth were not approved for hazardous locations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G07

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Mar 16, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 25909685T306

29 CFR 1910.107(g)(7): "NO SMOKING" sign(s) in large letters on contrasting color background were not conspicuously posted at all spraying areas:    a) On or about 09/22/15 - Main plant, spray booth, "NO SMOKING" sign(s) were not posted where flammable materials were being sprayed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Feb 14, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 250525909685

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a) On or about 09/22/15 - Main building, a written respirator program had not been established and implemented for the painter required to wear a Breathe-cool Supplied Air respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Jan 12, 2016
Abate by
Feb 14, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 2505258725909685

29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  a) On or about 09/22/15 - Main building, a written hazard communication program had not been developed for employee(s) exposed to paints and solvents such as Acrylic Enamel VSS Light Gray and Acetone and welding fumes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Valley Storm Shelters, LLC's full OSHA safety record →