Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUMMIT PRINCIPAL INVESTMENTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUMMIT PRINCIPAL INVESTMENTS, LLC in 1 WINDEMERE LANE, WELLESLEY, MA 02482 (NAICS 236118). OSHA activity number 340954809.

Watch Summit Principal Investments, LLC — free Get an email when a new federal OSHA severe-injury report for Summit Principal Investments, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1 WINDEMERE LANE
City
WELLESLEY
State
MA
ZIP
02482
Mailing
94 OAK STREET, WESTWOOD, MA 02090
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   Jobsite:  Subcontractor employees working on the roof were not protected against falls of up to approximately 20 feet.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.  Jobsite:  Extension ladder at front of building      The extension ladder used by subcontractor employees to access the roof did not extend at least 3 feet above the eave and the ladder was not secured to provide its displacement.
Recent events (1)
  • — Z (S) $2000

1926.1053 B07

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(7): Ladders were used on slippery surfaces:  Jobsite:  Extension ladder at front of house.  The extension ladder's feet rested on shingle debris that could cause the ladder to slip.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340954809.