Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLANTIC DRAIN SERVICE COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATLANTIC DRAIN SERVICE COMPANY, INC. in 5 CASTLE SQUARE 480 TREMONT STREET, BOSTON, MA 02116 (NAICS 237110). OSHA activity number 340954890.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Drain Service Company, INC. — free Get an email when a new federal OSHA severe-injury report for Atlantic Drain Service Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5 CASTLE SQUARE 480 TREMONT STREET
City
BOSTON
State
MA
ZIP
02116
Mailing
435R HYDE PARK AVENUE, ROSLINDALE, MA 02131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

9 citations on file for this inspection.

1903.19 D01

Other-than-serious 8 instances 5 exposed
Issued
Aug 19, 2016
Abate by
Sep 26, 2016
Penalty
Initial $400 · Current $400
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  The employer did not submit the required abatement documentation within 10 calendar days of the abatement dates.
Recent events (1)
  • — Z (O) $400

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $2,640 · Current $2,640
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  Jobsite:  Employees working in a tunnel did not wear hard hats to protect their heads from impacting the 'walls' or top of the tunnel.
Recent events (1)
  • — Z (S) $2640

1926.405 A02 II G

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.405(a)(2)(ii)(G): Portable electric lighting used in wet and/or other conductive locations (e.g., drums, tanks, and vessels) which was operating at more than 12 volts was not protected by a ground-fault circuit interrupter. undefined :   Jobsite:  A temporary lighting 'string' used to light the tunnel was plugged into a non-GFCI outlet on a light fixture in a Mechanical Room.
Recent events (1)
  • — Z (S) $2200

1926.800 J01 II A

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.800(j)(1)(ii)(A): The atmosphere in all underground work areas was not tested as often as necessary to ensure that the atmosphere contained at least 19.5 percent oxygen and no more than 22 percent oxygen:  Job site:  The company did not perform any testing to assess oxygen concentrations in the tunnel.
Recent events (1)
  • — Z (S) $2200

1926.800 J01 III A

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.800(j)(1)(iii)(A): The atmosphere in all underground work areas was not tested quantitatively for carbon monoxide, nitrogen dioxide, hydrogen sulfide, and other toxic gases, dusts, vapors, mists, and fumes as often as necessary to ensure that permissible exposure limits prescribed in 1926.55 are not exceeded.  Jobsite:  The company performed no air monitoring to assess employee exposure to hydrogen sulfide and other toxic gases likely to be present due to leaking sewer lines.
Recent events (1)
  • — Z (S) $0

1926.800 J01 III B

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.800(j)(1)(iii)(B): The atmosphere in all underground work areas was not tested quantitatively for methane and other flammable gases as often as necessary to determine (1)-(2):  Jobsite:  The employer did not test the tunnel air for methane and other flammable gasses.
Recent events (1)
  • — Z (S) $0

1926.800 K04

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Apr 19, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.800(k)(4): The direction of mechanical airflow for ventilation provided in underground construction work areas was not reversible:  Jobsite:  The Vactor 2100 hydro-excavator is only able to draw air from the work zone.  It can not supply air.
Recent events (1)
  • — Z (S) $2200

1926.800 D

Repeat Gravity 10 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Apr 19, 2016
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.800(d): Safety instruction. All employees were not instructed in the recognition and avoidance of hazards associated with underground construction activities including, where appropriate, the subjects listed in 29 CFR 1826.800 (d)(1) through (d)(10).  Jobsite:  Employees were not trained in the recognition and avoidance of tunnel hazards such as personal protective equipment, air monitoring for respiratory hazards, ventilation and emergency procedures.  Atlantic Drain Service Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.800(d)), which was contained in OSHA inspection number 1067512, citation number 1, item number 2 and was affirmed as a final order on September 10, 2015, with respect to a workplace located at 341 Tremont Street in Boston, MA.
Recent events (1)
  • — Z (R) $6160

1926.800 G05 II

Repeat Gravity 10 1 instance 3 exposed
Issued
Mar 22, 2016
Abate by
Mar 30, 2016
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.800(g)(5)(ii): On jobsites where less than 25 employees worked underground at one time, the employer did not provide or arrange in advance for at least one 5-person rescue team:  Jobsite:  No five person Rescue Team was available to rescue the two employees in the tunnel.  Atlantic Drain Service Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.800 (g)(5)(ii)), which was contained in OSHA inspection number 1067512, citation number 1, item number 4 and was affirmed as a final order on September 15, 2015, with respect to a workplace located at 341 Tremont Street in Boston, MA.
Recent events (1)
  • — Z (R) $6160

View Atlantic Drain Service Company, INC.'s full OSHA safety record →