BOSTON, MA —
OSHA Inspection: ATLANTIC DRAIN SERVICE COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ATLANTIC DRAIN SERVICE COMPANY, INC. in 5 CASTLE SQUARE 480 TREMONT STREET, BOSTON, MA 02116 (NAICS 237110). OSHA activity number 340954890.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATLANTIC DRAIN SERVICE COMPANY, INC.
- Site address
- 5 CASTLE SQUARE 480 TREMONT STREET
- City
- BOSTON
- State
- MA
- ZIP
- 02116
- Mailing
- 435R HYDE PARK AVENUE, ROSLINDALE, MA 02131
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1903.19 D01
- Issued
- Aug 19, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: The employer did not submit the required abatement documentation within 10 calendar days of the abatement dates.
Recent events (1)
- — Z (O) $400
1926.100 A
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,640 · Current $2,640
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Jobsite: Employees working in a tunnel did not wear hard hats to protect their heads from impacting the 'walls' or top of the tunnel.
Recent events (1)
- — Z (S) $2640
1926.405 A02 II G
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(G): Portable electric lighting used in wet and/or other conductive locations (e.g., drums, tanks, and vessels) which was operating at more than 12 volts was not protected by a ground-fault circuit interrupter. undefined : Jobsite: A temporary lighting 'string' used to light the tunnel was plugged into a non-GFCI outlet on a light fixture in a Mechanical Room.
Recent events (1)
- — Z (S) $2200
1926.800 J01 II A
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.800(j)(1)(ii)(A): The atmosphere in all underground work areas was not tested as often as necessary to ensure that the atmosphere contained at least 19.5 percent oxygen and no more than 22 percent oxygen: Job site: The company did not perform any testing to assess oxygen concentrations in the tunnel.
Recent events (1)
- — Z (S) $2200
1926.800 J01 III A
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.800(j)(1)(iii)(A): The atmosphere in all underground work areas was not tested quantitatively for carbon monoxide, nitrogen dioxide, hydrogen sulfide, and other toxic gases, dusts, vapors, mists, and fumes as often as necessary to ensure that permissible exposure limits prescribed in 1926.55 are not exceeded. Jobsite: The company performed no air monitoring to assess employee exposure to hydrogen sulfide and other toxic gases likely to be present due to leaking sewer lines.
Recent events (1)
- — Z (S) $0
1926.800 J01 III B
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.800(j)(1)(iii)(B): The atmosphere in all underground work areas was not tested quantitatively for methane and other flammable gases as often as necessary to determine (1)-(2): Jobsite: The employer did not test the tunnel air for methane and other flammable gasses.
Recent events (1)
- — Z (S) $0
1926.800 K04
- Issued
- Mar 22, 2016
- Abate by
- Apr 19, 2016
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.800(k)(4): The direction of mechanical airflow for ventilation provided in underground construction work areas was not reversible: Jobsite: The Vactor 2100 hydro-excavator is only able to draw air from the work zone. It can not supply air.
Recent events (1)
- — Z (S) $2200
1926.800 D
- Issued
- Mar 22, 2016
- Abate by
- Apr 19, 2016
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.800(d): Safety instruction. All employees were not instructed in the recognition and avoidance of hazards associated with underground construction activities including, where appropriate, the subjects listed in 29 CFR 1826.800 (d)(1) through (d)(10). Jobsite: Employees were not trained in the recognition and avoidance of tunnel hazards such as personal protective equipment, air monitoring for respiratory hazards, ventilation and emergency procedures. Atlantic Drain Service Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.800(d)), which was contained in OSHA inspection number 1067512, citation number 1, item number 2 and was affirmed as a final order on September 10, 2015, with respect to a workplace located at 341 Tremont Street in Boston, MA.
Recent events (1)
- — Z (R) $6160
1926.800 G05 II
- Issued
- Mar 22, 2016
- Abate by
- Mar 30, 2016
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.800(g)(5)(ii): On jobsites where less than 25 employees worked underground at one time, the employer did not provide or arrange in advance for at least one 5-person rescue team: Jobsite: No five person Rescue Team was available to rescue the two employees in the tunnel. Atlantic Drain Service Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.800 (g)(5)(ii)), which was contained in OSHA inspection number 1067512, citation number 1, item number 4 and was affirmed as a final order on September 15, 2015, with respect to a workplace located at 341 Tremont Street in Boston, MA.
Recent events (1)
- — Z (R) $6160
More inspections at Atlantic Drain Service Company, INC.
View Atlantic Drain Service Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340954890.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.