Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KILLEEN MACHINE TOOL CO. INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KILLEEN MACHINE TOOL CO. INC. in 33 HERMON ST., WORCESTER, MA 01610 (NAICS 332116). OSHA activity number 340957364.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Killeen Machine Tool CO. INC. — free Get an email when a new federal OSHA severe-injury report for Killeen Machine Tool CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
33 HERMON ST.
City
WORCESTER
State
MA
ZIP
01610
Mailing
33 HERMON ST., WORCESTER, MA 01610
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
49
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 17, 2016
Abate by
May 16, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about 10/5/2015 and at times prior throughout the facility at 33 Hermon St., Worcester, MA 01610 the employer had not developed written specific energy control procedures to control energy sources when performing maintenance, servicing, etc., for equipment such as, but not limited to, Minster Press, Model #E2-200, S/N E2-200-21337.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.147 C05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 17, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only:  On or about 10/6/2015 in Department 94, 33 Hermon Street, Worcester, MA 01610 and at times earlier employees were exposed to hazards from hazardous energy resulting from the use of Lockout and tagout devices to prevent unauthorized startup during normal operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 17, 2016
Abate by
May 16, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about 10/5/2015 and at times prior throughout the facility at 33 Hermon St., Worcester, MA 01610, periodic inspections of energy control procedures had not been conducted annually, nor within a 12 month period.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.147 C06 II

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 17, 2016
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  On or about 10/5/2015 and at times prior throughout the facility at 33 Hermon St., Worcester, MA 01610 periodic inspections of energy control procedures were not certified.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 20 exposed
Issued
Feb 17, 2016
Abate by
May 16, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.   On or about 1/26/2016 and at times prior throughout the facility at 33 Hermon St., Worcester, MA 01610 authorized employee Lock out Tag out training did not include training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.212 A02

Serious Gravity 5 11 instances 5 exposed
Issued
Feb 17, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  On or about 10/6/2015 and at times prior in the machine shop portable machine guards were used in lieu of fixed guards on machines such as, but not limited to Bridgeport Series I, milling machines.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

View Killeen Machine Tool CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340957364.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.