Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAKANISHI MANUFACTURING CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NAKANISHI MANUFACTURING CORPORATION in 1225 VYOLES ROAD, WINTERVILLE, GA 30683 (NAICS 336310). OSHA activity number 340957661.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nakanishi Manufacturing Corporation — free Get an email when a new federal OSHA severe-injury report for Nakanishi Manufacturing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1225 VYOLES ROAD
City
WINTERVILLE
State
GA
ZIP
30683
Mailing
1225 VOYLES ROAD, WINTERVILLE, GA 30683
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336310
Employees
153
Ownership type
A

13 citations on file for this inspection.

1910.22 C

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 23, 2016
Abate by
Apr 18, 2016
Penalty
Initial $2,700 · Current $1,900 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.  On 10/1/15, in the G-3 surface treatment area, the employer did not provide protection around the G3 Surface Treatment pit as they access the machine and parts.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2700

1910.147 C04 II

Serious Gravity 10 1 instance 25 exposed
Issued
Mar 23, 2016
Abate by
Mar 30, 2017
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section.  On 10/1/15, at the Athens facility, the employer did not create specific written procedures for equipment at the facility for equipment including but not limited to: presses, dust collectors, wet blasters, lathes, etc.. The employer did not implement specific written procedures according to the standard in that the following deficiencies existed:  a - A specific statement of the intended use of the procedure. b - Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. c - Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. d - Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 25 exposed
Issued
Mar 23, 2016
Abate by
Mar 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  On 10/1/15, at the Athens facility, the employer did not perform a periodic inspection to written Lockout procedures that were established at the facility to correct for deficiencies and did not include Authorized employees in the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 25 exposed
Issued
Mar 23, 2016
Abate by
Mar 30, 2017
Penalty
Initial $6,300 · Current $4,400 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On 10/1/15, in the production area, employees performing "Authorized" work are not identified and trained  by the company as "Authorized" persons in the established Lockout Tagout Program and are not provided locks for the service/maintenance work they provide.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $6300

1910.147 C07 I B

Serious Gravity 1 1 instance 25 exposed
Issued
Mar 23, 2016
Abate by
May 9, 2016
Penalty
Initial $2,700 · Current $1,900 Reduced
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure.  On 10/1/15, at the Athens facility, the employer did not instruct each Affected employee in the purpose and use of the company's energy control procedure.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2700

1910.178 L04 III

Serious Gravity 5 1 instance 25 exposed
Issued
Mar 23, 2016
Abate by
May 31, 2016
Penalty
Initial $4,500 · Current $3,500 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years.  On 10/1/15, the employer was not conducting an evaluation of powered industrial truck operator's performance at least once every three years.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4500

1910.212 A01

Serious Gravity 10 18 instances 25 exposed
Issued
Mar 23, 2016
Abate by
May 31, 2016
Penalty
Initial $6,300 · Current $4,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating and moving parts, flying chips and sparks.  On 10/1/15, in the production area, the employer did not guard machines from hazards created by ingoing nip points, rotating and moving parts. Instances included the following:  a - NKC strut lathe #2 Loader Assembly b - Dobby Rivet #2 product slide  c - Dobby Rivet #7 SS Cleaner (aka the oil shower) d - Dobby Rivet #7 product slide  e - Radial Packing Machine #10 SS Cleaner (aka the oil shower) f - Radial Packing Machine #10 Heaping Counter  g - Radial Packing Machine #11 SS Cleaner (aka the oil shower) h - Radial Packing Machine #11 Heaping Counter i - Mori Seki lathe (#59013) j - Okuma & Howa (# 48303 and #59016)  2 count k - Trak K3 (#400526) l - Mori Seki YD2-55 drill press (#400437) m - Kalamazoo Cut off Saw   n - Shigiya G-20 (#400493)  o - Shigiya G-20 (#59011) p - Leblond Makino (#400495)  q - Radial Press #3 conveyor  r - Radial Press #1 Conveyor
Recent events (2)
  • — I (S) $4400
  • — Z (S) $6300

1910.217 C01 I

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 23, 2016
Abate by
Apr 18, 2016
Penalty
Initial $4,500 · Current $3,500 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es).  On 10/1/15, in the Radial Press area, the employer did not install guards that protected to point of operation according to the standard Table O-10). Instances included:   a - Radial Press 7 - Infeed Opening - 7 in (w) x 4.6 in (h) x 15 in to point of operation b - Radial Press 3 - Out feed Opening - 24 in wide x 6 in (h) x 21 in to point of operation
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4500

1910.217 D09 IV

Serious Gravity 10 1 instance 15 exposed
Issued
Mar 23, 2016
Abate by
Jul 15, 2016
Penalty
Initial $6,300 · Current $5,000 Reduced
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press.  On 10/1/15, in the press production area, the employer did not enforce the use of safety blocks when mechanical press dies were being adjusted in the press.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $6300

1910.219 F03

Serious Gravity 5 4 instances 5 exposed
Issued
Mar 23, 2016
Abate by
May 31, 2016
Penalty
Initial $4,500 · Current $3,500 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.  On 10/1/15, in production areas, chain and sprockets were not guarded at the following area:  a - at the Auto Rack Conveyor - 22 in from floor levels b - at the Taper Centrifugal Separator conveyor in Surface Treatment room - 4 in from floor levels c - at the Wheelabrator conveyor in Surface Treatment room - 4 in from floor levels d - at Dobby Rivet Press #2 - within 3 in of operator controls
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4500

1910.303 G01

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 23, 2016
Abate by
Jul 15, 2016
Penalty
Initial $2,700 · Current $1,900 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.   On 10/1/15, in the Taper Surface Treatment room, electrical disconnects located on the A-side of the room are blocked by conveyors and cannot be accessed.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2700

1910.305 G02 III

Deleted Serious Gravity 1 3 instances 5 exposed
Issued
Mar 23, 2016
Abate by
Apr 18, 2016
Penalty
Initial $2,700 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  On 10/1/15, in the Radial Press area, the strain relief on 200 v. conveyor motor electrical cords were pulled away and separated and had not been reconnected. Instances included: Radial Press Conveyor 1, 2, and 3.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

1910.212 A01

Willful Gravity 10 4 instances 6 exposed
Issued
Mar 23, 2016
Abate by
Apr 18, 2016
Penalty
Initial $63,000 · Current $50,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating parts, flying chips and sparks.  On 10/1/15, in the Radial Press area, the employer did not guard pinch points on the following machines: Radial Press 6, 7, 9, and 10, a.k.a "Whopper Feeders".
Recent events (2)
  • — I (W) $50000
  • — Z (W) $63000

View Nakanishi Manufacturing Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340957661.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.