MARSHFIELD, WI —
OSHA Inspection: SERENITY DESIGNS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SERENITY DESIGNS in 1703 S CENTRAL AVE, MARSHFIELD, WI 54449 (NAICS 332812). OSHA activity number 340957737.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SERENITY DESIGNS
- Site address
- 1703 S CENTRAL AVE
- City
- MARSHFIELD
- State
- WI
- ZIP
- 54449
- Mailing
- 1703 S CENTRAL AVE, MARSHFIELD, WI 54449
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.107 C03
- Issued
- Feb 4, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.107(c)(3): Hot surfaces. Space-heating appliances, steampipes, or hot surfaces were located in a spraying area where deposits of combustible residues may readily accumulate: On or about October 1, 2015, the ceiling-mounted unit heater and curing oven were located in the powdered paint spraying area where combustible residues could readily accumulate.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.107 C07
- Issued
- Feb 4, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(7): Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, were not protected from mechanical injury by suitable guards or by location: On or about October 1, 2015, fluorescent lamps mounted on the ceiling and walls of the powder paint spraying area were not protected from mechanical injury.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.107 L01
- Issued
- Feb 4, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(l)(1): Electrical and other sources of ignition. Electrical equipment and other sources of ignition did not conform to the requirements of paragraphs (c)(1) (i)-(iv), (8) and (9)(i) of this section and subpart S of this part: On or about October 1, 2015, electrical wiring and equipment in the powdered paint area did not confirm to subpart S in that the wiring and equipment was not rated for Class II dust. The list of equipment includes, but is not limited to, the power pack for the powdered paint applicator, the oven, fluorescent lights, and a portable radio.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 L07 II
- Issued
- Feb 4, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(l)(7)(ii): Transformers, powerpacks, control apparatus, and all other electrical portions of the equipment, with the exception of the charging electrodes and their connections to the power supply were not located outside of the powder coating area and did not otherwise conform to the requirements of paragraph (l)(1) of this section: On or about October 1, 2015, the power pack and control apparatus for powder paint application were located inside the powder coating area and this equipment was not rated for Class II dust.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 L04 I
- Issued
- Feb 4, 2016
- Abate by
- Mar 31, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dusts, particularly such horizontal surfaces as ledges, beams, pipes, hoods, booths, and floors: On or about October 1, 2015, horizontal surfaces in the powder coating area were not kept free of accumulations of powdered paint dust. The list of horizontal surfaces includes, but is not limited to, the oven top, the unit heater top, and miscellaneous shelves and work table surfaces.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at Serenity Designs
View Serenity Designs's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340957737.