Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A POTTS CONSTRUCTION COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A POTTS CONSTRUCTION COMPANY, LLC in 146 VLY ROAD, COLONIE, NY 12205 (NAICS 238910). OSHA activity number 340958305.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A Potts Construction Company, LLC — free Get an email when a new federal OSHA severe-injury report for A Potts Construction Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
146 VLY ROAD
City
COLONIE
State
NY
ZIP
12205
Mailing
1050 KINGS ROAD, SCHENECTADY, NY 12303
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 2, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.  An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift:    a) Worksite - On or about October 2, 2015, a competent person did conduct an inspection of a 5 feet 9 inch deep excavation that did not have an adequate cave-in protective system in place.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 2, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    a) Worksite - On or about October 2, 2015, employees were exposed to caught-in hazards due to working in an approximately  5 feet 9 inch deep excavation without an adequate cave-in protective system in place.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340958305.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.