Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN STEEL SERVICES, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of AMERICAN STEEL SERVICES, INC. in 1083 S YORK RD, ELMHURST, IL 60126 (NAICS 238120). OSHA activity number 340958925.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Steel Services, INC. — free Get an email when a new federal OSHA severe-injury report for American Steel Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1083 S YORK RD
City
ELMHURST
State
IL
ZIP
60126
Mailing
840 BRIAN DRIVE, CREST HILL, IL 60403
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
A

8 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part.    On or about September 28, 2015, employees performing steel erection work activities were exposed to struck-by hazards associated with unsecured steel joists and metal decking.  The employer did not initiate and maintain such programs to address the hazards associated with the erection of steel joists and metal decking.       Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)    On or about September 28, 2015, an employee performing steel erection work activities was exposed to struck-by hazards associated with unsecured steel joists and metal decking.  The employer did not provide a competent person to make frequent and regular inspections of the job site and materials.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.757 A06

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1926.757(a)(6): When steel joist(s) are landed on a structure, they shall be secured to prevent unintentional displacement prior to installation.    On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer did not ensure that the steel joists were secured to prevent unintentional displacement prior to installation.  The employer had placed twenty-eight steel joists without securing the joists to the supporting wall structures.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1926.757 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.757(b)(3): Except as provided in paragraph (b)(4) of this section, each steel joist shall be attached to the support structure, at least at one end on both sides of the seat, immediately upon placement in the final erection position and before additional joists are placed.    On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer did not ensure that the steel joists were attached to the structure immediately upon placement in the final erection position.  The employer had placed twenty-eight steel joists without securing the joists to the supporting wall structures.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.757 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1926.757(e)(1): During the construction period, the employer placing a load on steel joists shall ensure that the load is distributed so as not to exceed the carrying capacity of any steel joist.    On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer placed load of metal decking on steel joists that was not distributed so as not to exceed the carrying capacity of any steel joist.       Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1926.757 E02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.757(e)(2): Except for paragraph (e)(4) of this section, no construction loads are allowed on the steel joists until all bridging is installed and anchored and all joist-bearing ends are attached.    On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer placed load of metal decking on steel joists that was not secured by the installation and anchorage of bridging.       Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.757 E05

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.757(e)(5): The edge of the construction load shall be placed within 1 foot (.30 m) of the bearing surface of the joist end.    On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer placed load of metal decking in the middle of a twenty-three feet span of steel joists.        Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.759 A

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.759(a): All materials, equipment, and tools which were not in use while aloft, were not secured against accidental displacement.     On or about September 28, 2016, employees engaged in steel erection work activities were exposed to struck by hazards when the employer did not ensure that sheets of metal decking attached to the structure.  The employer had placed three bundles of metal decking and partially distributed decking sheets over some twenty-eight steel joists without securing the decking to the joists.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

View American Steel Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340958925.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.