WELLESLEY, MA —
OSHA Inspection: REYNOLDS ELECTRICAL CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of REYNOLDS ELECTRICAL CO., INC. in 21 CROWN RIDGE ROAD, WELLESLEY, MA 02482 (NAICS 238210). OSHA activity number 340959279.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REYNOLDS ELECTRICAL CO., INC.
- Site address
- 21 CROWN RIDGE ROAD
- City
- WELLESLEY
- State
- MA
- ZIP
- 02482
- Mailing
- 471 WASHINGTON STREET, WELLESLEY, MA 02481
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 23, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Jobsite: roof Employees working on a roof were exposed to a fall hazard of up to approximately 14.5 feet.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.503 A01
- Issued
- Nov 23, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Jobsite: Employees have not been adequately trained in fall hazards and fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B03
- Issued
- Nov 23, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(3): Ladders were loaded beyond their manufacturer's rated capacity: Location: rear deck The ladder used to access the roof had a rated capacity of 200 pounds. It was used by employees who weighed in excess of 200 pounds.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1060 A
- Issued
- Nov 23, 2015
- Abate by
- Jan 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: Location: Job site Employees have not received adequate ladder safety training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238210)