BEDFORD, PA —
OSHA Inspection: BEDFORD REINFORCED PLASTICS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BEDFORD REINFORCED PLASTICS in 264 REYNOLDSDALE ROAD, BEDFORD, PA 15522 (NAICS 326199). OSHA activity number 340960863.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEDFORD REINFORCED PLASTICS
- Site address
- 264 REYNOLDSDALE ROAD
- City
- BEDFORD
- State
- PA
- ZIP
- 15522
- Mailing
- 264 REYNOLDSDALE ROAD, BEDFORD, PA 15522
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 243
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.305 B01 II
- Issued
- Nov 12, 2015
- Penalty
- Initial $2,700 · Current $2,025 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) Production Area, Line # 7 Electrical Box, on or about October 2, 2015 - Employees were exposed to electrical shock, arcing parts and/or fire hazards in that an unused breaker slot was not closed. b) Production Area, Line #7 Electrical Box, on or about October 2, 2015 - Employees were exposed to fire and arcing part hazards in that the knockout of the electric box was missing.
Recent events (2)
- — I (S) $2025
- — Z (S) $2700
1910.37 B05
- Issued
- Nov 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Mixing Building: On or about October 2, 2015 - A doorway in the Mixing Building was not marked "Not an Exit" or identified by a sign indicating its actual use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K06
- Issued
- Nov 12, 2015
- Abate by
- Nov 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Quality Control Area, on or about October 15, 2015 - The employer did not provide the basic advisory information on respirators as presented in Appendix D of the respirator standard to employees who wear dust masks voluntarily.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.145 C03
- Issued
- Nov 12, 2015
- Abate by
- Nov 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): a) Mixing Building, on or about October 2, 2015 - The employer did not use safety signs to designate material, material flow and pressure on the piping system between two resin holding tanks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340960863.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.