OSHA Inspection: SALMON RUN SHOPPING CENTER, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SALMON RUN SHOPPING CENTER, LLC in 21182 SALMON RUN MALL LOOP WEST, WATERTOWN, NY 13601 (NAICS 531120). OSHA activity number 340966589.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salmon RUN Shopping Center, LLC — free Get an email when a new federal OSHA severe-injury report for Salmon RUN Shopping Center, LLC is published. One employer, no account, unsubscribe in one click.
Site address
21182 SALMON RUN MALL LOOP WEST
City
WATERTOWN
State
NY
ZIP
13601
Mailing
21182 SALMON RUN MALL LOOP WEST, WATERTOWN, NY 13601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531120
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2015
Abate by
Jan 15, 2016
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     a) Center Court and Roof Top, on or about 10/6/2015: Employee performing maintenance on various types of equipment such as but not limited to HVAC units and installing electrical components was performing the work without following an energy control program.
Recent events (3)
  • — J (S) $2000
  • — C (S) $2000
  • — Z (S) $2000

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2015
Abate by
Jan 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Center Court and Roof Top, on or about 10/6/2015: Employee performing maintenance on various types of equipment such as but not limited to HVAC units and installing electrical components was performing the work without following a procedure on how to de-energized the equipment.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2015
Abate by
Jan 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    a) Center Court and Roof Top, on or about 10/6/2015: Employee performing maintenance on various types of equipment such as but not limited to HVAC units and installing electrical components was performing the work without having received training on the energy control program.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2015
Abate by
Jan 15, 2016
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    a) Center Court and Roof Top, on or about 10/6/2015: Employee performing maintenance on various types of equipment such as but not limited to HVAC units and installing electrical components were not provided with locks or tags to isolate the energy sources.
Recent events (3)
  • — J (S) $2000
  • — C (S) $2000
  • — Z (S) $2000

1910.157 G02

Other-than-serious 1 instance 3 exposed
Issued
Nov 9, 2015
Abate by
Jan 15, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:     a) Salmon Run Mall, on or about 10/6/2015:  Employees are expected to use the available fire extinguishers to fight incipient stage fires.
Recent events (3)