SCOTT CITY, MO —
OSHA Inspection: EMS USA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EMS USA in ROTH DRIVE, SCOTT CITY, MO 63780 (NAICS 237120). OSHA activity number 340967694.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMS USA
- Site address
- ROTH DRIVE
- City
- SCOTT CITY
- State
- MO
- ZIP
- 63780
- Mailing
- 5391 BAY OAKS DRIVE, PASADENA, TX 77505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 600
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 B04
- Issued
- Oct 14, 2015
- Abate by
- Mar 27, 2017
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was open, underground installations were not protected, supported or removed as necessary to safeguard employees: a/ At the job site, two, underground fiberoptic cables were not supported inside of a trench that measured approximately 70'L X 15'D X 20'W.
Recent events (3)
- — F (O) $4000
- — C (S) $4000
- — Z (S) $4000
1926.651 K02
- Issued
- Oct 14, 2015
- Abate by
- Mar 27, 2017
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: At the job site, the competent person assigned failed to identify and take corrective action to address the following hazards noted during the inspection: a/ At the job site, two, underground fiber optic cables were not supported inside of a trench that measured approximately 70'L X 15'D X 20'W. b/ At the job site, the slope belonging to the unsupported west wall was approximately 80 degrees from the horizontal. The trench where employees were observed working measured approximately 70'L X 15'D X 20'W.
Recent events (3)
- — F (O) $5000
- — C (S) $5000
- — Z (S) $5000
1926.652 A01
- Issued
- Oct 14, 2015
- Abate by
- Mar 27, 2017
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a/ At the job site, the slope belonging to the unsupported west wall was approximately 80 degrees from the horizontal. The trench where employees were observed working measured approximately 70'L X 15'D X 20'W.
Recent events (3)
- — F (O) $7000
- — C (S) $7000
- — Z (S) $7000
More inspections in this industry (NAICS 237120)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340967694.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.