SHARPSVILLE, PA —
OSHA Inspection: CREATIVE COATINGS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CREATIVE COATINGS, INC. in 111 MAIN STREET, SHARPSVILLE, PA 16150 (NAICS 238390). OSHA activity number 340969815.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CREATIVE COATINGS, INC.
- Site address
- 111 MAIN STREET
- City
- SHARPSVILLE
- State
- PA
- ZIP
- 16150
- Mailing
- 8551 HITCHCOCK ROAD, BOARDMAN, OH 44512
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.416 A01
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working within 5 feet of energized utility power lines while working from a tubular welded frame scaffold. Employees were conducting work operations from the scaffold that included, but were not limited to, plastering work. B.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times thereto, employees were working within 1 foot of an energized electrical drop service while working from a tubular welded frame scaffold. Employees were conducting work operations from the scaffold that included, but were not limited to, plastering work.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.451 F06
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working within 5 feet of energized utility power lines while working from a tubular welded frame scaffold. Employees were conducting work operations from the scaffold that included, but were not limited to, plastering work. The standard requires a 10 foot working clearance. B.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times thereto, employees were working within 1 foot of an energized electrical drop service while working from a tubular welded frame scaffold. The standard requires a 10 foot working clearance. Employees were conducting work operations from the scaffold that included but were not limited to, plastering work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working from a tubular welded frame scaffold that was not fully planked. Only about half of the level the employees were working had planking. The deck on the scaffold that the employees were working form was approximately 16 feet above ground level. Employees conducted work operations from the scaffold that included, but was not limited to, plastering work.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.451 F03
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working on a tubular welded frame scaffold that was not inspected by a competent person. The scaffold defects included, but were not limited to, the working level was only partially decked, some of the planks were in poor condition, the scaffold was too close to electrical lines, and the scaffolding was missing guardrails. Employees were working from the scaffold approximately 16 feet above the ground conduction work operations that included, but were not limited to, plastering work.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.454 A
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working on a tubular welded frame scaffold without having specific scaffold training to recognize hazards. The scaffold defects included, but were not limited to, the working level was only partially decked, some of the planks were in poor condition, the scaffold was too close to electrical lines, and the scaffolding was missing guardrails. Employees were working from the scaffold approximately 16 feet above the ground conduction work operations that included, but were not limited to, plastering work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: A.) Creative Coatings Inc., 111 Main Street, Sharpsville, PA - On or about 10/5/15, and at times prior thereto, employees were working from a tubular welded scaffold that did not have a guardrail system in place. The employees were not utilizing other means of fall protection. Employees were exposed to a fall hazard of 16 feet. Employees were performing work operations from the scaffold that included, but were not limited to, plastering work.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.1200 E01
- Issued
- Nov 6, 2015
- Abate by
- Jan 4, 2016
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A.) Creative Coating Inc. - On or about 10/5/15, and at times prior thereto, a written Hazard Communication program was not documented and implemented. Employees worked with paints and plastering products.
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
1910.1200 G01
- Issued
- Nov 6, 2015
- Abate by
- Dec 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Safety data sheets were not onsite for each chemical used: A.) Creative Coating Inc./Construction Site --- 111 Main Street Sharpsville, PA - On or about 10/5/15, and at times prior thereto, safety data sheets for the products the employees were utilizing were not located on site. Employees worked with paints and plastering products.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H
- Issued
- Nov 6, 2015
- Abate by
- Jan 4, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into the workplace: A.) Creative Coating Inc. - On or about 10/5/15, and at times prior thereto, employees had not received hazard communication training and specific training on the chemicals they worked with. Employees worked with paints and plastering products.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Creative Coatings, INC.
View Creative Coatings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340969815.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.