PASADENA, TX —
OSHA Inspection: MEMC PASADENA INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MEMC PASADENA INC in 3000 N SOUTH ST., PASADENA, TX 77503 (NAICS 325180). OSHA activity number 340970417.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEMC PASADENA INC
- Site address
- 3000 N SOUTH ST.
- City
- PASADENA
- State
- TX
- ZIP
- 77503
- Mailing
- 3000 N SOUTH ST., PASADENA, TX 77503
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325180
- Employees
- 194
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.119 D03 I B
- Issued
- Mar 21, 2016
- Abate by
- Apr 23, 2016
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer did not ensure that process safety information pertaining to the equipment in the process was included in the piping and instrument diagrams (P&IDs). On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, when the employer failed to include on the Piping and Instrument Diagram valves utilized for isolation in the 92300 on page 02-20-92-24-FD-06B for the following piping : a) 1" SLN-7424-151 / 1/2" FX-7415-154 (K-92350 Compressor) b) 4" SLN-7439-154 / 4" SLN-4829-154 / 1 1/2" SLN-7422B-154 / 1 1/2" SLN-7422A-304.2 (D-92350 1st Stage Inlet Dampener to K-92350 Compressor) c) 1 1/2" SLN-7422-304.2 / 2" FX-7417-154 (K92350 Compressor to D92351 2nd Stage Discharge Dampener) d) 2" WCS-7141-125 (To E-92353 Interstage Cooler) e) 2" FX-7419-154 (D-92352 to flare)
Recent events (1)
- — Z (S) $5000
1910.119 F04
- Issued
- Mar 21, 2016
- Abate by
- Apr 13, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; opening process equipment or piping. a) On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not follow the permitting procedure during the blinding process of the K92350 compressor to ensure that the employees involved had the appropriate Personal Protective Equipment (PPE) during the activity. b) On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not ensure proper isolation for the control of hazards during the lockout/tagout and blinding process, for the K92350 compressor.
Recent events (1)
- — Z (S) $7000
1910.132 D01 I
- Issued
- Mar 21, 2016
- Abate by
- Apr 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not have employees use Personal Protective Equipment (PPE) that would protect employees from the hazards associated with Silane; a) On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not ensure that the employees involved in blinding the K92350 compressor had the appropriate Personal Protective Equipment (PPE) during a line break.
Recent events (1)
- — Z (S) $0
1910.119 J02
- Issued
- Mar 21, 2016
- Abate by
- Apr 23, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.119(j)(2): The employer shall establish and implement written procedures to maintain the on-going integrity of process equipment. On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, when the employer failed to establish and implement an inspection plan for the following process piping in the 92300 Area: a) 1" SLN-7424-151 / 1/2" FX-7415-154 (K-92350 Compressor) b) 4" SLN-7439-154 / 4" SLN-4829-154 / 1 1/2" SLN-7422B-154 / 1 1/2" SLN-7422A-304.2 (D-92350 1st Stage Inlet Dampener to K-92350 Compressor) c) 1 1/2" SLN-7422-304.2 / 2" FX-7417-154 (K92350 Compressor to D92351 2nd Stage Discharge Dampener) d) 2" WCS-7141-125 (To E-92353 Interstage Cooler) e) 2" FX-7419-154 (D-92352 to flare)
Recent events (1)
- — Z (S) $7000
1910.147 C04 II B
- Issued
- Mar 21, 2016
- Abate by
- Apr 13, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The procedure did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not ensure that specific steps for isolation, blocking and securing the K92350 Silane compressor was in place before employees began blinding the system for maintenance.
Recent events (1)
- — Z (S) $7000
1910.147 C04 II D
- Issued
- Mar 21, 2016
- Abate by
- Apr 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The procedures did not have specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not ensure that specific requirements for testing the effectiveness of the isolation of the K92350 Silane compressor before employees began blinding the system for maintenance.
Recent events (1)
- — Z (S) $0
1910.147 D05 I
- Issued
- Mar 21, 2016
- Abate by
- Apr 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): The employer did not ensure that, following the application of lockout or tagout, devices to energy isolating devices, all potentially hazardous stored or residual energy was relieved, disconnected, restrained, and otherwise rendered safe. On or about October 2, 2015, and times prior to, at the MEMC Pasadena, Inc. facility in Pasadena, TX, the employer did not ensure that the K92350 compressor was free of Silane before employees began blinding the system for the preparation of maintenance.
Recent events (1)
- — Z (S) $0
More inspections at Memc Pasadena INC
View Memc Pasadena INC's full OSHA safety record →
More inspections in this industry (NAICS 325180)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340970417.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.