LOCKPORT, NY ·
OSHA Inspection: NIAGARA PRECISION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NIAGARA PRECISION INC. in 233 MARKET ST., LOCKPORT, NY 14094 (NAICS 332710). OSHA activity number 340971795.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NIAGARA PRECISION INC.
- Site address
- 233 MARKET ST.
- City
- LOCKPORT
- State
- NY
- ZIP
- 14094
- Mailing
- 233 MARKET ST., LOCKPORT, NY 14094
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 19
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 A02 II A
- Issued
- Nov 12, 2015
- Abate by
- Dec 12, 2015
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(a)(2)(ii)(A): Lockout/tagout procedures were not implemented when servicing and/or maintenance was taking place during normal production operations when an employee (s) was required to (A) Remove or bypass a guard or other safety device; (B) were required to place any part of his or her body into area on a machine or piece of equipment where work was actually performed upon the material being processed (point of operation) or where an associated danger zone existed during a machine operating cycle: a) On or about 10/09/2015, in the shop area when employees service machines, such as changing the blade on the horizontal band saw, energy control procedures were not being implemented. Exposing employees to unexpected start of energy. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1500
- · Z (S) $2000
1910.147 C06 II
- Issued
- Nov 12, 2015
- Abate by
- Dec 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the energy control procedure. a) On or about 10/09/2015, in the machine shop, employer fail to appropriately identify and document the machine or equipment on which the energy control procedure was being utilized, such as but not limited to horizontal band saw. ABATEMENT CERTIFICATION REQUIRED