ABILENE, TX —
OSHA Inspection: ALL STATE STUCCO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALL STATE STUCCO in CORNER OF CHAMPION AND BUFFALO GAP RD, ABILENE, TX 79608 (NAICS 238140). OSHA activity number 340972215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL STATE STUCCO
- Site address
- CORNER OF CHAMPION AND BUFFALO GAP RD
- City
- ABILENE
- State
- TX
- ZIP
- 79608
- Mailing
- 9704 US HWY 277, HAWLEY, TX 79525
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platforms: Employees engaged in rasping operations on the scaffold at the south side of the building were exposed to fall hazards from scaffold decks not being fully planked.
Recent events (3)
- — F (S) $1000
- — C (S) $2800
- — Z (S) $2800
1926.451 B01 I
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide. Employees engaged in rasping operations for stucco application at the south side of the building were exposed to fall hazards due to the spacing between the planks was greater than one inch.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.451 C02
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: Employees engaged in rasping operation prior to stucco at the south side of the building were exposed to caught in and fall hazards from not having mud sills for the erected scaffold.
Recent events (3)
- — F (O) $0
- — C (S) $2800
- — Z (S) $2800
1926.451 E01
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Employees engaged in rasping operation prior to stucco at the south side of the building were exposed to fall hazards from not using the ladder to access the top level of the scaffold.
Recent events (3)
- — F (S) $1000
- — C (S) $2800
- — Z (S) $2800
1926.451 F03
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,040 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. Employees engaged in rasping operations prior to stucco on a scaffold on the south side of the building were exposed to fall and caught in hazards from the employer failing to conduct an inspection of the scaffold the previous day.
Recent events (3)
- — F (S) $0
- — C (S) $2040
- — Z (S) $2040
1926.451 G01
- Issued
- Nov 19, 2015
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section. Employees were engaged in rasping operations prior to stucco from a scaffold in excess of ten feet along the south side of the building.
Recent events (3)
- — F (S) $1000
- — C (S) $2800
- — Z (S) $2800
1926.451 G04 I
- Issued
- Nov 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. Employees were engaged in rasping operations prior to stucco from a scaffold in excess of ten feet along the south side of the building.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340972215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.