On , OSHA opened a referral safety inspection of JUSTIN GRIDER in 1506 BEVERIDGE CT, EDWARDSVILLE, IL 62025 (NAICS 238160). OSHA activity number 340975200.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JUSTIN GRIDER
- Site address
- 1506 BEVERIDGE CT
- City
- EDWARDSVILLE
- State
- IL
- ZIP
- 62025
- Mailing
- 202 TROLLEY, SAWYERVILLE, IL 62085
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 D01
- Issued
- Feb 4, 2016
- Abate by
- Mar 6, 2016
- Penalty
- Initial $440 · Current $440
General-duty citation text
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a) For Citation 1, Item 1, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA. b) For Citation 1, Item 2, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA. c) For Citation 1, Item 3, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA. d) For Citation 1, Item 4, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA. e) For Citation 2, Item 1, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.
Recent events (1)
- — Z (O) $440
1926.307 D01
- Issued
- Dec 14, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs (m) and (o) of this section: A gasoline-powered air compressor was being used for roofing activities at a residential house and the pulley, belt and parts were not guarded.
Recent events (1)
- — Z (S) $2200
1926.1053 B01
- Issued
- Dec 14, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A.) A blue extension ladder was being used to access the roof of a residential house located at 1506 Beveridge Court, Edwardsville, IL 62025 and the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed. B.) A red extension ladder was being used to access the roof of a residential house located at 1506 Beveridge Court, Edwardsville, IL 62025 and the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed.
Recent events (1)
- — Z (S) $3080
1926.1053 B04
- Issued
- Dec 14, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: A Werner extension ladder was not being used for the purpose for which it was designed. The base section and fly section of the ladder were separated and the fly section was used to access the roof of a residential house.
Recent events (1)
- — Z (S) $1760
1926.1053 B16
- Issued
- Dec 14, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: A.) A Werner extension ladder had structural defects, such as but not limited to, broken rungs, and was being used to access the roof of a residential house. The ladder was not marked in a manner that readily identified it as defective, tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired. B.) A red extension ladder had structural defects, such as but not limited to, broken rails, and was being used to access the roof of a residential house. The ladder was not marked in a manner that readily identified it as defective, tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired.
Recent events (1)
- — Z (S) $2200
1926.501 B13
- Issued
- Dec 14, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $15,400 · Current $15,400
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Employees were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or any other approved mean. Employees were in the process of installing a new roof and were exposed to the hazard of falling approximately eleven (11) to fourteen (14) feet.
Recent events (1)
- — Z (W) $15400
More inspections at Justin Grider
View Justin Grider's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340975200.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.