Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JUSTIN GRIDER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JUSTIN GRIDER in 1506 BEVERIDGE CT, EDWARDSVILLE, IL 62025 (NAICS 238160). OSHA activity number 340975200.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Justin Grider — free Get an email when a new federal OSHA severe-injury report for Justin Grider is published. One employer, no account, unsubscribe in one click.
Establishment
JUSTIN GRIDER
Site address
1506 BEVERIDGE CT
City
EDWARDSVILLE
State
IL
ZIP
62025
Mailing
202 TROLLEY, SAWYERVILLE, IL 62085
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

6 citations on file for this inspection.

1903.19 D01

Other-than-serious 4 instances 3 exposed
Issued
Feb 4, 2016
Abate by
Mar 6, 2016
Penalty
Initial $440 · Current $440
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  a)  For Citation 1, Item 1, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.  b)  For Citation 1, Item 2, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.  c)  For Citation 1, Item 3, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.  d)  For Citation 1, Item 4, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.  e)  For Citation 2, Item 1, issued on 12/14/2015 with an abatement date of 12/18/2015, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.
Recent events (1)
  • — Z (O) $440

1926.307 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 14, 2015
Abate by
Dec 18, 2015
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs  (m) and  (o) of this section:  A gasoline-powered air compressor was being used for roofing activities at a residential house and the pulley, belt and parts were not guarded.
Recent events (1)
  • — Z (S) $2200

1926.1053 B01

Serious Gravity 10 2 instances 3 exposed
Issued
Dec 14, 2015
Abate by
Dec 18, 2015
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  A.) A blue extension ladder was being used to access the roof of a residential house located at 1506 Beveridge Court, Edwardsville, IL 62025 and the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed.  B.) A red extension ladder was being used to access the roof of a residential house located at 1506 Beveridge Court, Edwardsville, IL 62025 and the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed.
Recent events (1)
  • — Z (S) $3080

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 14, 2015
Abate by
Dec 18, 2015
Penalty
Initial $1,760 · Current $1,760
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  A Werner extension ladder was not being used for the purpose for which it was designed. The base section and fly section of the ladder were separated and the fly section was used to access the roof of a residential house.
Recent events (1)
  • — Z (S) $1760

1926.1053 B16

Serious Gravity 5 2 instances 3 exposed
Issued
Dec 14, 2015
Abate by
Dec 18, 2015
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  A.) A Werner extension ladder had structural defects, such as but not limited to, broken rungs, and was being used to access the roof of a residential house. The ladder was not marked in a manner that readily identified it as defective, tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired.   B.) A red extension ladder had structural defects, such as but not limited to, broken rails, and was being used to access the roof of a residential house.  The ladder was not marked in a manner that readily identified it as defective, tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired.
Recent events (1)
  • — Z (S) $2200

1926.501 B13

Willful Gravity 10 1 instance 3 exposed
Issued
Dec 14, 2015
Abate by
Dec 18, 2015
Penalty
Initial $15,400 · Current $15,400
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   Employees were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or any other approved mean. Employees were in the process of installing a new roof and were exposed to the hazard of falling approximately eleven (11) to fourteen (14) feet.
Recent events (1)
  • — Z (W) $15400

View Justin Grider's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340975200.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.