Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANTEK

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANTEK in 1353 INTERNATIONAL DRIVE, EAU CLAIRE, WI 54701 (NAICS 326199). OSHA activity number 340982792.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advantek — free Get an email when a new federal OSHA severe-injury report for Advantek is published. One employer, no account, unsubscribe in one click.
Establishment
ADVANTEK
Site address
1353 INTERNATIONAL DRIVE
City
EAU CLAIRE
State
WI
ZIP
54701
Mailing
1353 INTERNATIONAL DRIVE, EAU CLAIRE, WI 54701
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
50
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) P2 carrier film area; Lockout procedures were not documented and utilized to isolate hazardous energy sources associated with activities, such as but not limited to cleaning, servicing, and setting up the P2 carrier lines.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1910.147 C07 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    (a) Throughout the facility; Each employee who worked on locked out equipment was not trained as authorized to lockout.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 2 instances 15 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    (a) P2 carrier film lines; energy isolation devices were not located and operated to isolate energy source during setup and cleaning operations:  i. Energy isolation devices were not used during setup operations on the punch section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 2 instances 15 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) P2 Carrier film lines; Energy isolation devices were not attached to isolation point(s) during service work, such as but not limited to setting up equipment and cleaning operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 10 6 instances 13 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:    (a) P2 carrier film area; Punch section guards on P2 carrier film lines were not secured and/or safeguarded to prevent them from being easily bypassed.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1910.212 A03

Serious Gravity 5 6 instances 13 exposed
Issued
Mar 7, 2016
Abate by
May 2, 2016
Penalty
Initial $3,500 · Current $2,800 Reduced
29 CFR 1910.212(a)(3): Point of operation guard(s) were not provided:    (a) P2 carrier film area; Point-of-operation guarding was not provided on the outfeed side of punch section on P2 carrier film lines.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $3500

1910.147 C04 II C

Other-than-serious 1 instance 30 exposed
Issued
Mar 7, 2016
Abate by
Apr 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:   (a) Throughout the facility; The energy control procedure did not identify means for removing or transferring energy isolation devices or tagout devices.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Advantek's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340982792.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.