VINELAND, NJ —
OSHA Inspection: DANDREA PRODUCE INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DANDREA PRODUCE INC. in 3665 N. MILL ROAD, VINELAND, NJ 08360 (NAICS 424480). OSHA activity number 340982834.
Where did this inspection happen?
- Establishment
- DANDREA PRODUCE INC.
- Site address
- 3665 N. MILL ROAD
- City
- VINELAND
- State
- NJ
- ZIP
- 08360
- Mailing
- 3665 N. MILL ROAD, VINELAND, NJ 08360
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424480
- Employees
- 70
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1155.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Dandrea Produce Inc. - Repacking area: The employer did not ensure that employees wore safety glasses while performing cleaning operations with the compressed air nozzle, on or about 06/18/2015.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. a) Dandrea Produce Inc. - Repacking area: Compressed air used for cleaning purposes by employees was measured at 120 p.s.i., observed on or about 06/18/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 G02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1540.00 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks: a) Dandrea Produce Inc. - Forklift charging area: The facility did not protect the battery charging apparatuses from damage. The charging cables on a Depth battery charger Model # D3E2-18-950, serial #BA74026, had damaged cords with exposed copper conduit, observed on or about 06/18/2015.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1155.00 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Dandrea Produce Inc. - Repacking area: Top heavy machinery such as a Ryoby drill press, Model # DPI21L, S/N AZ092947226 was not bolted to the surface below, observed on or about 06/18/2015.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1155.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating: a) Dandrea Produce Inc. - Repacking area: An outlet box had a damaged cover that did not protect the wires inside from accidental damage, observed on or about 06/18/2015.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1910.303 C03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a) Dandrea Produce Inc. - Repacking area: The cable from the welding machine had a visible splice covered with masking tape, observed on or about 06/18/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Dandrea Produce Inc. - Repacking area: The conveyor machine next to the Giro Bagger GB/UB machine, model # US 7100658, S/N 328-000700 had a damaged strain relief , observed on or about 06/18/2015. a) Dandrea Produce Inc. - Maintenance area: The outlet cable powering the welding equipment had a damaged strain relief , observed on or about 06/18/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) Dandrea Produce Inc. - Repacking area: The employer did not ensure that each container of hazardous chemical used in the workplace containing simple green, etc., was mark or labeled with its contents, on or about 06/18/2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424480)
DEPEW, NY—2026-07-07
FRUIT FRESH UP INC
PLANT CITY, FL—2026-06-30
FLORIDA POTATO & ONION, L.L.C.
WIMAUMA, FL—2026-06-22
TOMATO THYME CORPORATION
YAKIMA, WA—2026-06-15
WA317991674 - WASHINGTON FRUIT & PRODUCE CO
VIDALIA, GA—2026-06-11
GEORGIA ONION PROCESSOR LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340982834.