Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANDRIY IVANTSIV

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANDRIY IVANTSIV in 2419 W. HURON ST., CHICAGO, IL 60612 (NAICS 238140). OSHA activity number 340989110.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andriy Ivantsiv — free Get an email when a new federal OSHA severe-injury report for Andriy Ivantsiv is published. One employer, no account, unsubscribe in one click.
Establishment
ANDRIY IVANTSIV
Site address
2419 W. HURON ST.
City
CHICAGO
State
IL
ZIP
60612
Mailing
2511 W CHICAGO AVE 2 FL, CHICAGO, IL 60622
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 28, 2015
Abate by
Jan 25, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a. On or about October 15, 2015, at the above addressed jobsite, an employee was operating a powered industrial vehicle (Gradall 534D9-45) during material handling operations. The operator of the powered industrial truck did not complete the required training and evaluation specified in paragraph (l).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 4, 2016
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    a. On or about October 15, 2015, at the above addressed jobsite, employees were conducting masonry operations from a tubular welded frame scaffold, approximately twenty-six (26) feet above the lower surface, that was not fully planked, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews:  a. On or about October 15, 2015, at the above addressed jobsite, employees were conducting masonry operations from a tubular welded frame scaffold, approximately twenty six (26) feet above the lower surface, which was not provided with a complete guardrail system, thereby exposing employees to the hazards associated with falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold:  a. On or about October 15, 2015, at the above addressed jobsite, employees were conducting masonry operations from a tubular welded frame scaffold, approximately twenty-six (26) feet above the lower surface, were not protected from falls, thereby exposing employees to hazards associated with falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 4, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access:    a. On or about October 15, 2015, at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold which was not provided with an access ladder, thereby exposing employees to the hazards associated with falls.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340989110.