Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: READIING ALLOYS, INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of READIING ALLOYS, INCORPORATED in OLD WEST PENN AVENUE, ROBESONIA, PA 19551 (NAICS 331112). OSHA activity number 340990662.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Readiing Alloys, Incorporated — free Get an email when a new federal OSHA severe-injury report for Readiing Alloys, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
OLD WEST PENN AVENUE
City
ROBESONIA
State
PA
ZIP
19551
Mailing
P.O. BOX 53, ROBESONIA, PA 19551
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331112
Employees
650
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 25 exposed
Issued
Apr 8, 2016
Abate by
Dec 30, 2016
Penalty
Initial $7,000 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm from a metal dust fire or explosion hazard:  Reading Alloys, Building 11, North outside of Building -  Employees were exposed to fire and explosion hazards from the dust Collector/Baghouse 18, which collected combustible metal dust from process equipment inside building. The baghouse dry filter media in baghouse 18 were not antistatic in nature nor were they grounded while in use to prevent dust ignition from a static charge and/or spark. In addition, the placement of the isolation flap valve was not in position to prevent the energy of the dust deflagration from reentering the building to prevent damage to the process equipment on or about October 8, 2015.