RAMSEY, NJ —
OSHA Inspection: ACS CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACS CONSTRUCTION LLC in 247 AIRMOUNT AVE, RAMSEY, NJ 07446 (NAICS 238130). OSHA activity number 340992122.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACS CONSTRUCTION LLC
- Site address
- 247 AIRMOUNT AVE
- City
- RAMSEY
- State
- NJ
- ZIP
- 07446
- Mailing
- 1440 GERH PLACE, NORTH BERGEN, NJ 07047
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 4, 2015
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a-Exterior Structure: An employee was exposed to eye injury hazards while using a pneumatic nailer in which eye protection was not utilized. Condition noted on or about 10/16/2015
Recent events (2)
- — I (S) $800
- — Z (S) $2000
1926.451 C02
- Issued
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: A- Pump Jack Scaffold: CSHO observed employees engaged in siding work from a pump jack scaffold in which the supporting legs were not provided a firm foundation. Condition noted on or about 11/04/2015
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.451 F06
- Issued
- Dec 4, 2015
- Abate by
- Dec 16, 2015
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a-Exterior Structure: Employees were exposed to electrocution hazards when a pump jack scaffold was erected within 12 inches of an energized secondary power source. Condition noted on or about 10/16/2015 b-Pump Jack Scaffold: An employee was exposed to electrocution hazards while engaged in siding work within 12 inches of an energized secondary power source. Condition noted on or about 11/04/2015.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.451 G01
- Issued
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection. a-Pump Jack Scaffold: Employees engaged in siding work were exposed to fall hazards of approximately 15ft to the ground below as a means of fall protection was not utilized. Condition noted on or about 11/04/2015
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.452 J02
- Issued
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a-Pump Jack Scaffold: Scaffold support legs were not braced at the base exposing the workers to scaffold kick-out and collapse. Condition noted on or about 11/04/2015.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.501 B13
- Issued
- Dec 4, 2015
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a-Exterior Structure : An employee was exposed to fall hazards of approximately 15ft from an exterior porch roof while engaged in roofing activities on an exterior porch in which a means of fall protection was not utilized. Condition noted on or about 10/16/2015
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
More inspections at ACS Construction LLC
View ACS Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340992122.