OSHA Inspection: AEON PROCESS EQUIPMENT & CONTROL SOLUTIONS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AEON PROCESS EQUIPMENT & CONTROL SOLUTIONS, INC. in 505 AERO DR., SHREVEPORT, LA 71137 (NAICS 332911). OSHA activity number 340992544.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aeon Process Equipment & Control Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Aeon Process Equipment & Control Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
505 AERO DR.
City
SHREVEPORT
State
LA
ZIP
71137
Mailing
505 AERO DR., SHREVEPORT, LA 71137
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332911
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.212 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 9, 2015
Abate by
Dec 24, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible.  On or about October 15, 2015 at jobsite located at 505 Aero Dr, Shreveport, LA 71137, the employer allowed employees to operate a Mori Seiki Lathe without a guard attached.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.253 B02 IV

Serious Gravity 5 5 instances 1 exposed
Issued
Dec 9, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.  On or about October 15, 2015 at jobsite located at 505 Aero Dr, Shreveport, LA, the employer throughout the warehouse establishment,  had pressurized cylinder tanks without valve covering caps.           a. On the south side of the warehouse in the welding/fabrication area, one (1) compressed Argon cylinder was secured to a frame without a valve cover cap.             b. At the center of the warehouse, one (1) Compressed Argon pressurized cylinder was secured to a steel beam without a valve cover cap.           c. In the storage area for cylinders, the employer had two (2) full Acetylene pressurized cylinders without a valve cover cap on it.          d. In the empty storage area for cylinders, the employer had four (4) Oxygen pressurized cylinders without a valve cover cap on it.          e. In the storage area for cylinders, the employer had two (2), Nitrogen pressurized cylinders without a valve cover cap on it.