SHREVEPORT, LA —
OSHA Inspection: AEON PROCESS EQUIPMENT & CONTROL SOLUTIONS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of AEON PROCESS EQUIPMENT & CONTROL SOLUTIONS, INC. in 505 AERO DR., SHREVEPORT, LA 71137 (NAICS 332911). OSHA activity number 340992544.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AEON PROCESS EQUIPMENT & CONTROL SOLUTIONS, INC.
- Site address
- 505 AERO DR.
- City
- SHREVEPORT
- State
- LA
- ZIP
- 71137
- Mailing
- 505 AERO DR., SHREVEPORT, LA 71137
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A02
- Issued
- Dec 9, 2015
- Abate by
- Dec 24, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible. On or about October 15, 2015 at jobsite located at 505 Aero Dr, Shreveport, LA 71137, the employer allowed employees to operate a Mori Seiki Lathe without a guard attached.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.253 B02 IV
- Issued
- Dec 9, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use. On or about October 15, 2015 at jobsite located at 505 Aero Dr, Shreveport, LA, the employer throughout the warehouse establishment, had pressurized cylinder tanks without valve covering caps. a. On the south side of the warehouse in the welding/fabrication area, one (1) compressed Argon cylinder was secured to a frame without a valve cover cap. b. At the center of the warehouse, one (1) Compressed Argon pressurized cylinder was secured to a steel beam without a valve cover cap. c. In the storage area for cylinders, the employer had two (2) full Acetylene pressurized cylinders without a valve cover cap on it. d. In the empty storage area for cylinders, the employer had four (4) Oxygen pressurized cylinders without a valve cover cap on it. e. In the storage area for cylinders, the employer had two (2), Nitrogen pressurized cylinders without a valve cover cap on it.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
More inspections in this industry (NAICS 332911)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340992544.