LUBBOCK, TX —
OSHA Inspection: BREEDLOVE FOODS INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BREEDLOVE FOODS INC in 1818 N. MARTIN LUTHER KING JR. BLVD., LUBBOCK, TX 79403 (NAICS 311999). OSHA activity number 340996107.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BREEDLOVE FOODS INC
- Site address
- 1818 N. MARTIN LUTHER KING JR. BLVD.
- City
- LUBBOCK
- State
- TX
- ZIP
- 79403
- Mailing
- 1818 N. MARTIN LUTHER KING JR. BLVD., LUBBOCK, TX 79403
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 57
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputation hazards while working around augers: On or about October 15, 2015, employees of Breedlove Foods, Inc., were exposed to caught-in and amputation hazards while performing cleaning work around the blancher feed by the auger that was not provided with an emergency stop.
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.22 A02
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: Employees of Breedlove Foods, Inc., were exposed to slip and fall hazards while working and/or walking in areas that were wet and not maintained in a dry condition at the Dry Room.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.37 A03
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Employees of Breedlove Foods, Inc., were exposed to physical and health hazards while working in the Raw Area where exit routes were not kept free from clutter or overflow materials.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.38 E
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.38(e): Training. An employer must designate and train employees to assist in a safe and orderly evacuation of other employees. Employees of Breedlove Foods, Inc., were not designated and trained by the employer to assist other employees in a safe and orderly evacuation of the building upon an emergency.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.144 A01 III
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.144(a)(1)(iii): Stop. Emergency stop bars on hazardous machines such as rubber mills, wire blocks, flat work ironers, etc., shall be red. Stop buttons or electrical switches which letters or other markings appear, used for emergency stopping of machinery shall be red. On or about October 15, 2015, employees of Breedlove Foods, Inc., were exposed to struck by and caught in hazards while working on the dry room equipment when the equipment emergency stop was not red.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.147 C01
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about October 15, 2015, the employer, Breedlove Foods, Inc., exposed employees to electrical shock hazards while they worked on the Blancher.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.147 C04 I
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 15, 2015, the employer, Breedlove Foods, Inc., exposed employees to caught in and electrical shock hazards when they did not utilize a specific procedure for the blancher feed auger to ensure the employees are properly locking out all energy sources when performing maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.147 C06 I
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: On or about October 15, 2015, the employees of Breedlove Foods, Inc., were exposed to the hazard of being struck-by or caught in the equipment when the employer did not conduct an annual or more frequent inspection of the energy control procedure by each authorized personnel to ensure that they were properly implemented during repair and service work on the blancher, blancher feed auger, dicer and peeler.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.147 C07 I
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about October 15, 2015, the employer did not provide training on energy control (lockout/tag out) program to ensure that all required elements of the program were understood by all authorized employees whose work operations were, or may be in an area where energy control procedures are utilized.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.212 A01
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. The employer did not ensure that guarding was provided to prevent employee contact with moving parts in the Dry Room and the Potato Receiving Area at: a. The hopper motor; b. The shaft on the corner of the inspection table; c. The surge inclines belts; d. Bin infeed roller conveyor- located outside in the potato receiving station.
Recent events (2)
- — I (S) $4200
- — Z (S) $4200
1910.303 B07 IV
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. Employees of Breedlove Foods, Inc., are being exposed to electrical hazards when employer does not ensures electrical panel boxes are deteriorated by corrosion at the: 1. Bin controls in the Raw Room; 2. Bin infeed roller conveyor controls in the outdoors Potato Receiving area; 3. Potato receiving belt operation panel in the Raw Room; 4. Emergency stop control on the inspection tables at the Dry Room.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.303 G01 II
- Issued
- Apr 12, 2016
- Abate by
- Apr 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing: Employees of Breedlove Foods Inc., were exposed to burn and struck- by hazards, in the Raw Room next to the bins, while access to electrical panels was blocked by the flume flow control valve mounted on PVC pipe lines.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
More inspections at Breedlove Foods INC
View Breedlove Foods INC's full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340996107.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.