Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PHILIP J. STOFANAK, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PHILIP J. STOFANAK, INC. in 176 NAZARETH PIKE, BETHLEHEM, PA 18018 (NAICS 337110). OSHA activity number 340997907.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Philip J. Stofanak, INC. — free Get an email when a new federal OSHA severe-injury report for Philip J. Stofanak, INC. is published. One employer, no account, unsubscribe in one click.
Site address
176 NAZARETH PIKE
City
BETHLEHEM
State
PA
ZIP
18018
Mailing
176 NAZARETH PIKE, BETHLEHEM, PA 18018
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.134 C

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 25, 2016
Abate by
Feb 11, 2016
Penalty
Initial $1,360 · Current $1,020 Reduced
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:    a. Wood shop and Spray Booth- On or about October 21, 2015, employees were using respirators during spray finishing operations involving paints containing organic vapors including isocyanates, but the employer did not develop and implement a respirator program with worksite specific procedures and elements for required respirator use.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1360

1910.134 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 25, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a. Wood shop and Spray Booth - On or about October 21, 2015,   Employees use respirators while spray painting with paints containing isocyanates and other organic chemicals, but the employer did not provide a medical evaluation for these employees prior to the respirator's use in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 25, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a) Wood shop and Spray Booth - On or about October 21, 2015, employees were required to wear elastomeric respirators while performing spray finishing work, utilizing paints containing organic chemicals including isocyanates, but the employer did not provide respirator fit testing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 25, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary.  The employer shall ensure that each employee can demonstrate knowledge of at least the sections (k)(1) (i through vii) :  a) Wood shop and Spray Booth - On or about October 21, 2015, employees were required to wear elastomeric respirators while performing spray finishing work, utilizing paints containing organic chemicals including isocyanates, but the employer did not provide respirator training to each respirator user.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 25, 2016
Penalty
Initial $2,040 · Current $1,530 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.    a) Wood Shop - On or about October 21, 2015, employees were using a circuit breaker panel with a missing breaker cover over live parts energized to 120 volts AC , exposing employees to the risk of electrical shock.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2040

1910.303 F

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 25, 2016
Abate by
Feb 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    a) Shop area- On or about October 21, 2015, employees were using unlabeled circuit breakers to control equipment located in the shop area, such as, but not limited to, the grinder, lighting, and receptacles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 25, 2016
Abate by
Feb 22, 2016
Penalty
Initial $2,040 · Current $1,530 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Facility wide - On or about October 21, 2015, employees were using extension cords as a substitute for the fixed wiring of a structure.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2040

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 25, 2016
Abate by
Feb 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a) Shop area- On or about October 21, 2015, employees were using extension cords which did not have strain relief in place to prevent tension at the joints or terminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 II

Other-than-serious 1 instance 6 exposed
Issued
Jan 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  a) Maintenance shop area - On or about October 21, 2015, employees were using unlabeled secondary containers containing hazardous chemicals.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Philip J. Stofanak, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340997907.