BETHLEHEM, PA —
OSHA Inspection: PHILIP J. STOFANAK, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PHILIP J. STOFANAK, INC. in 176 NAZARETH PIKE, BETHLEHEM, PA 18018 (NAICS 337110). OSHA activity number 340997907.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PHILIP J. STOFANAK, INC.
- Site address
- 176 NAZARETH PIKE
- City
- BETHLEHEM
- State
- PA
- ZIP
- 18018
- Mailing
- 176 NAZARETH PIKE, BETHLEHEM, PA 18018
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.134 C
- Issued
- Jan 25, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $1,360 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a. Wood shop and Spray Booth- On or about October 21, 2015, employees were using respirators during spray finishing operations involving paints containing organic vapors including isocyanates, but the employer did not develop and implement a respirator program with worksite specific procedures and elements for required respirator use.
Recent events (2)
- — I (S) $1020
- — Z (S) $1360
1910.134 E01
- Issued
- Jan 25, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Wood shop and Spray Booth - On or about October 21, 2015, Employees use respirators while spray painting with paints containing isocyanates and other organic chemicals, but the employer did not provide a medical evaluation for these employees prior to the respirator's use in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Jan 25, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Wood shop and Spray Booth - On or about October 21, 2015, employees were required to wear elastomeric respirators while performing spray finishing work, utilizing paints containing organic chemicals including isocyanates, but the employer did not provide respirator fit testing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Jan 25, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary. The employer shall ensure that each employee can demonstrate knowledge of at least the sections (k)(1) (i through vii) : a) Wood shop and Spray Booth - On or about October 21, 2015, employees were required to wear elastomeric respirators while performing spray finishing work, utilizing paints containing organic chemicals including isocyanates, but the employer did not provide respirator training to each respirator user.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Jan 25, 2016
- Penalty
- Initial $2,040 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a) Wood Shop - On or about October 21, 2015, employees were using a circuit breaker panel with a missing breaker cover over live parts energized to 120 volts AC , exposing employees to the risk of electrical shock.
Recent events (2)
- — I (S) $1530
- — Z (S) $2040
1910.303 F
- Issued
- Jan 25, 2016
- Abate by
- Feb 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. a) Shop area- On or about October 21, 2015, employees were using unlabeled circuit breakers to control equipment located in the shop area, such as, but not limited to, the grinder, lighting, and receptacles.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jan 25, 2016
- Abate by
- Feb 22, 2016
- Penalty
- Initial $2,040 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Facility wide - On or about October 21, 2015, employees were using extension cords as a substitute for the fixed wiring of a structure.
Recent events (2)
- — I (S) $1530
- — Z (S) $2040
1910.305 G02 III
- Issued
- Jan 25, 2016
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Shop area- On or about October 21, 2015, employees were using extension cords which did not have strain relief in place to prevent tension at the joints or terminal screws.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Jan 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) Maintenance shop area - On or about October 21, 2015, employees were using unlabeled secondary containers containing hazardous chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Philip J. Stofanak, INC.
View Philip J. Stofanak, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340997907.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.