DALLAS, TX —
OSHA Inspection: PANEL TRUSS - DALLAS, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PANEL TRUSS - DALLAS, LLC in 8290 SOUTH CENTRAL EXPRESSWAY, DALLAS, TX 75241 (NAICS 321214). OSHA activity number 340997915.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PANEL TRUSS - DALLAS, LLC
- Site address
- 8290 SOUTH CENTRAL EXPRESSWAY
- City
- DALLAS
- State
- TX
- ZIP
- 75241
- Mailing
- 8290 SOUTH CENTRAL EXPRESSWAY, DALLAS, TX 75241
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 C01
- Issued
- Nov 16, 2015
- Abate by
- Jan 5, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about October 22, 2015, the employer had not administered a hearing conservation program for employees exposed to noise that exceeded an 8-hour time-weighted average (TWA) of 85 dBA, based on an 80 dB threshold: (a) In the floor production area, a lead worker was exposed to noise levels at 103.4% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 103.4% is approximately 90.2 dBA. Sampling was performed for 470 minutes during one shift. Zero exposure was assumed for the unsampled period of 10 minutes. (b) In the floor production area, a worker was exposed to noise levels at 191.8% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 191.8% is approximately 94.7 dBA. Sampling was performed for 460 minutes during one shift. Zero exposure was assumed for the unsampled period of 20 minutes. (c) In the floor production area, a worker was exposed to noise levels at 112.9% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 112.9% is approximately 90.8 dBA. Sampling was performed for 468 minutes during one shift. Zero exposure was assumed for the unsampled period of 12 minutes. (d) In the floor production area, a worker was exposed to noise levels at 97.78% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 97.78% is approximately 89.8 dBA. Sampling was performed for 465 minutes during one shift. Zero exposure was assumed for the unsampled period of 15 minutes. (e) In the roof production area, a worker was exposed to noise levels at 164.3% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 164.3% is approximately 93.5 dBA. Sampling was performed for 465 minutes during one shift. Zero exposure was assumed for the unsampled period of 15 minutes. (f) In the roof production area, a worker was exposed to noise levels at 138.0% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 138.0% is approximately 92.3 dBA. Sampling was performed for 469 minutes during one shift. Zero exposure was assumed for the unsampled period of 11 minutes. (g) In the roof production area, a worker was exposed to noise levels at 72.01% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 72.01% is approximately 87.6 dBA. Sampling was performed for 469 minutes during one shift. Zero exposure was assumed for the unsampled period of 11 minutes. (h) In the production shop, a support worker was exposed to noise levels at 97.04% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 97.04% is approximately 89.7 dBA. Sampling was performed for 472 minutes during one shift. Zero exposure was assumed for the unsampled period of 8 minutes.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.95 I02 I
- Issued
- Nov 16, 2015
- Abate by
- Nov 20, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
8110
General-duty citation text
29 CFR 1910.95(i)(2)(i): The employer did not ensure that hearing protectors are worn by an employee who is required by 29 CFR 1910.95(b)(1) to wear personal protective equipment: On or about October 22, 2015, the employer did not ensure that hearing protectors were worn by employees who were exposed to noise that exceeded an 8-hour time-weighted average (TWA) of 90 dBA, based on a 90 dB threshold: (a) In the floor production area, a worker was exposed to noise levels at 174.0% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 174.0% is approximately 94.0 dBA. Sampling was performed for 460 minutes during one shift. Zero exposure was assumed for the unsampled period of 20 minutes. (a) In the roof production area, a worker was exposed to noise levels at 139.0% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 139.0% is approximately 92.3 dBA. Sampling was performed for 465 minutes during one shift. Zero exposure was assumed for the unsampled period of 15 minutes.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections at Panel Truss - Dallas, LLC
View Panel Truss - Dallas, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321214)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340997915.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.