Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BURGESS SNYDER INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BURGESS SNYDER INDUSTRIES, INC. in JOINT EXPEDITIONARY BASE FORT STORY, VIRGINIA BEACH, VA 23459 (NAICS 238150). OSHA activity number 341001261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Burgess Snyder Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Burgess Snyder Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
JOINT EXPEDITIONARY BASE FORT STORY
City
VIRGINIA BEACH
State
VA
ZIP
23459
Mailing
560 BAKER ROAD, VIRGINIA BEACH, VA 23462
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 28, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a)    Joint Expeditionary Base Fort Story, BEQ Renovation, buildings B860-862: On or about 10/20/2015, an orange 50 foot extension cord plugged into a 115 volts wall receptacle used to supply power to a portable electric cork cutter was not protected with a ground fault circuit interrupter device or an assured grounding program, as a result employees were exposed to possible burns resulting from electrical shock.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

View Burgess Snyder Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341001261.